User`s manual

LBI-39117
15
NOTE
At this point in the set-up process, if the
NETCLOCK/2™ option is enabled, time display at
the console(s) and error/warning logging time
stamps at the CEC Manager will be synchronized
to WWVB.
REDUNDANT CLOCK CONFIGURATION
The Compact CEC is factory-equipped with one (1)
Clock Board which has redundant (back-up) clock circuits.
These circuits provide clock pulse timing signals for the
Audio Boards' TDM bus circuits across the upper Card Cage
(Card Cage 1). The lower Card Cage (the CIA rack – Card
Cage 2) does not require and is not equipped with any Clock
Boards.
If back-up clocking is desired, this option must be
activated by enabling it from the CEC Manager's
"
MOM Configuration
" screen.
NOTE
When only one Clock Board is installed in the
Compact CEC, both toggle switches – "A" and "B"
on the front of the board – must be turned on before
redundant clock operation is possible.
NOTE
NOTE