User`s manual

LBI-39117
12
Conventional Interface Boards
CI Boards within the CIA Card Cage – Card Cage 2
have one 8-position DIP switch which allows configuration
of the following board parameters: "site" number, test mode
enable/disable, watchdog timer enable/disable, and board
number.
At the factory, before installation into the Card Cage,
each CI Board DIP switch is set in accordance with the DIP
Switch Settings diagram in this manual (Card Cage 2, slots 3
and 5). Normally, CI Board DIP switch changes are never
required during the installation and set-up process of a
Compact CEC.
NOTE
If, during servicing/troubleshooting procedures for
example, a CI Board must be moved to a different
Card Cage slot, its DIP switch should be set in
accordance with the DIP Switch Settings diagram
in this manual for the particular Card Cage slot
which it will be installed within.
Uplink GETC
Within the GETC, there are three 8-position DIP
switches. These switches are located on the lower left-hand
side of the GETC's Logic Board. Together with the GETC's
personality programming, they allow the GETC to be
configured for various applications such an uplink, a
downlink, or a station GETC. The GETC in the Compact
CEC is always configured for uplink operation by setting the
DIP switches as shown in Figure 4. Unlike most other
GETC applications, a GETC configured for uplink operation
does not require any personality programming.
As shown in Figure 4, all DIP switches on an
uplink GETC except S1 position 8 should be in the
"CLOSED" or "ON" position. S1 position 8
should be in the "OPEN" or "OFF" position. This
is the factory setting. Verify the GETC's switches
are setting accordingly. If any DIP switch changes
are made, reset the GETC by pressing the reset
button on the Logic Board.
Uplink GETC DIP switch changes from the above
described should never be required unless, for example,
during servicing procedures, a non-uplink configured GETC
is substituted in place of the existing uplink GETC. In this
case, the substitute GETC's DIP switches must be
configured for uplink operation as described in the previous
paragraph before proper uplink operation will occur. In
addition, the substitute GETC's jumpers and cables must
also be configured for uplink operation. See EDACS Site
Downlink & CEC/IMC Uplink GETC Configuration
Manual, LBI-38896, for additional details. After any GETC
DIP switch change, the GETC should be reset by pressing
the reset button on its Logic Board.
Figure 4 – Uplink GETC DIP Switch Settings
INITIAL MOM CONFIGURATION
The very first Compact CEC configuration from the
CEC Manager involves setting up CEC Manager users and
several high-level MOM parameters as described in
LBI-38938. Set-up the following parameters in accordance
with LBI-38938:
CEC Manager Users
– Enter user names and an
access level and a password for each user.
Afterwards, delete the default user name and
password – "MOMUSER" and "GUEST"
respectively.
MOM Parameters
– Set baud rates, disable data
logging, enable or disable printer status, disable
redundant clocks, and disable unit logout timers. If
required, data logging and redundant clocks may be
enabled at a later time; however, these items should
be disabled for the time being.
System Time And Date
– Enter the date and time
at the CEC Manager. If the Spectracom
NETCLOCK/2™ equipment (optional) is included,
do not perform the NETCLOCK/2 set-up at this
time.
SYSTEM MANAGER UPLOAD
(If Present)
Transfer or "upload" unit, group and site data from
the System Manager to the Compact CEC in
accordance with LBI-38938 and LBI-38911/
LBI-39024/LBI-39124/etc.
TDM BUS AND SLOT CONFIGURATION
From the CEC Manager, set-up TDM bus and slot
parameters as follows. See LBI-38938 for additional details:
TDM Bus Configuration
– Configure the
Compact CEC for 8-bus Audio Boards.
- - - - - - - - - OPEN - - - - - - - -
-
12345678
S1
- - - - - - - - - OPEN - - - - - - - -
-
12345678
S2
- - - - - - - - - OPEN - - - - - - - -
-
12345678
S3
S1-8 = "OPEN".
ALL OTHER SWITCHES "CLOSED".
NOTE