Reference Manual Part 6
Table Of Contents
- FBTEST Reference Manual
- 1 Introduction
- 2 Installation Procedures
- 3 Hardware, Equipment and Preparation
- 4 FBTEST User Modes
- 5 User Interface Description
- 6 Main Menu
- 6.1 Board Test Menu
- 6.1.1 Alt. 1: Do the Test
- 6.1.2 Alt. 2: Number of Test Cycles
- 6.1.3 Alt. 3: Select/Unselect Boards
- 6.1.4 Alt. 4: Select Extended Test
- 6.1.5 Alt. 5: Select Medium Test
- 6.1.6 Alt. 6: Unselect all Tests
- 6.1.7 Alt. 7-11: Sets the Test Parameters for Each Board
- 6.1.8 Alt.7: Set Parameters for FCB–FE Computer Board
- 6.1.9 Alt. 8: Set Parameters for FRB–FE Radio Board
- 6.1.10 Alt. 9: Set Parameters for FNB–FE Connection Board
- 6.1.11 Alt. 10: Set Parameters for FMB–FE Modem Board
- 6.1.12 Alt. 11: Set Params for FPB–FE Power Supply Board
- 6.1.13 Alt.12: Look at Test Results
- 6.2 Set Time
- 6.3 Radio Operations
- 6.4 Measurement Setup Menu
- 6.4.1 Transceiver Control and Presentation Menu
- 6.4.2 Radio Calibration Menu
- 6.4.3 Bandgap Calibration
- 6.4.4 Temperature Sensor Calibration
- 6.4.5 Reference Oscillator OCXO Calibration
- 6.4.6 PF Output Power Calibration
- 6.4.7 PR Reflected Power Calibration
- 6.4.8 VCO Modulation Calibration
- 6.4.9 TCXO Modulation Calibration
- 6.4.10 RSSI Calibration
- 6.4.11 EEPROM Display Editor Menu
- 6.4.12 PA Bias and FDAC Calibration Menu
- 6.4.13 Radio Register Editor Menu
- 6.4.14 Adjustment
- 6.4.15 Setup
- 6.5 Modem Operation Menu
- 6.6 Status Overview Menu
- 6.7 Edit Loader Parameters Menu
- 6.1 Board Test Menu
- 7 Index
FBTEST REFERENCE MANUAL 3 (102)
BRU3 MANUAL, Doc.no: 198 17-CAAA 808 288 Uen Rev H, 2003-06-06
1 Introduction
FBTEST is a test program for the Base Radio Unit 3 - BRU3. Two types of user
interfaces are available through a serial communication port. One by a menu-
oriented structure where test alternatives and parameters are selected by
stepping through the menus. The other interface is by command frame input,
suitable for automatic testing with computer supervision over a communication
line. In this case, the command frame syntax is the user interface. This is not
described in this document. The test program is operated using a console
terminal, connected to the BRU3, on which the result is displayed.
A negative test result indicates a hardware fault, but a positive test result does
not guarantee that the hardware is OK. It is not possible to test everything with
this test program.
1.1 Field of Application
There are four main applications for the FBTEST:
• Acceptance control of the BRU3 hardware
• Validating a new node
• Trouble-shooting an existing node
• Set up of node specific Loader parameters.
The FBTEST Reference Manual covers both the procedures required when
calibrating the BRU3’s components at the factory, and the on-site installation
and commissioning procedures for the BRU3.