Reference Manual

Table Of Contents
98 (110) BRU1/BRU3 MANUAL
BRU1/BRU3 MANUAL, Doc.no: b3fb_ref Uen Rev PJ5, 2004-02-19
Alt. 4 BIT RATE
A toggle function between bit rates 1200, 2400, 4800, 9600 and
14400, where the bit rate normally should be set to 9600, but it is
possible to select other rates by toggling.
Note: This bit rate setting is related to asynchronous communication
(sending initiation commands to the modem).
Alt. 5 DIAL TIMEOUT
The Dial Timeout in seconds should be entered.
Dial timeout [sec][0 - 500]: (0)
The value should normally be 60 sec.
Alt. 6 ANSWER TIMEOUT
The Answer Timeout in seconds should be entered.
Answer timeout [sec][0 - 500]: (0)
The value should normally be 60 sec.
RETRY TIMEOUT
The (Answer) Retry Timeout in (milliseconds) seconds should be
entered.
Answer timeout [sec][0 - 600000]: (0)
The value should normally be 600000.
RETRY TIMEOUT is used when control type ATHAYES_LL has
been selected. The value controls how often the modem tries to
connect to the leased line. The established dial-up connection is
disconnected during theses attempts.
Alt. 7 INIT COMMANDS
Displays the Prompt - Modem Parameter - Init Command menu in
Figure 56.