Reference Manual
Table Of Contents
- FBTEST Reference Manual
- 1 Introduction
- 2 Installation Procedures
- 3 Hardware, Equipment and Preparation
- 4 FBTEST User Modes
- 5 User Interface Description
- 6 Main Menu
- 6.1 Board Test Menu
- 6.1.1 Alt. 1: Do the Test
- 6.1.2 Alt. 2: Number of Test Cycles
- 6.1.3 Alt. 3: Select/Unselect Boards
- 6.1.4 Alt. 4: Select Extended Test
- 6.1.5 Alt. 5: Select Medium Test
- 6.1.6 Alt. 6: Unselect all Tests
- 6.1.7 Alt. 7-11: Sets the Test Parameters for Each Board
- 6.1.8 Alt.7: Set Parameters for FCB–FE Computer Board
- 6.1.9 Alt. 8: Set Parameters for FRB–FE Radio Board
- 6.1.10 Alt. 9: Set Parameters for FNB–FE Connection Board (BRU3 only)
- 6.1.11 Alt. 10 (BRU3): Set Parameters for FMB–FE Modem Board
- 6.1.12 Alt. 10 (BRU1): Set Parameters for FIB - FE Interface Board
- 6.1.13 Alt. 11: Set Params for FPB–FE Power Supply Board (BRU3 only)
- 6.1.14 Alt.12: Look at Test Results
- 6.2 Set Time
- 6.3 Radio Operations
- 6.4 Measurement Setup Menu
- 6.4.1 Transceiver Control and Presentation Menu
- 6.4.2 Radio Calibration Menu
- 6.4.3 Bandgap Calibration
- 6.4.4 Temperature Sensor Calibration
- 6.4.5 Reference Oscillator OCXO Calibration
- 6.4.6 PF Output Power Calibration
- 6.4.7 PR Reflected Power Calibration
- 6.4.8 VCO Modulation Calibration
- 6.4.9 TCXO Modulation Calibration
- 6.4.10 RSSI Calibration
- 6.4.11 EEPROM Display Editor Menu
- 6.4.12 PA Bias and FDAC Calibration Menu
- 6.4.13 Radio Register Editor Menu
- 6.4.14 Adjustment
- 6.4.15 Setup
- 6.5 Modem Operation Menu (BRU3 only)
- 6.6 Interface Board Parameters Menu (BRU1 only)
- 6.7 Status Overview Menu
- 6.8 Edit Loader Parameters Menu (BRU3 and System Release R14 only)
- 6.1 Board Test Menu
FBTEST REFERENCE MANUAL 73 (110)
BRU1/BRU3 MANUAL, Doc.no: b3fb_ref Uen Rev PJ5, 2004-02-19
6.4.10 RSSI Calibration
[Main menu, Radio Operations, Calibration, RSSI Calibration]
Status Line:
Operational conditions
The transmitter and receiver conditions are shown, as described in the
transceiver control and presentation menu. The operation conditions are
changed in Radio Calibration Menu.
Reference values
The measured input signal RSSI, is shown for reference points R1 - R10.
Figure 37 RSSI Calibration menu.
RSSI Calibration SYS:yyyy-mm-dd hh:mm
Current test selection is MEDIUM
TX: OFF TXCH: 3840 PF: 0 TXSEND:OFF RXCH: 3040
RSSI INDEX: 2
T1 T2 T3 T4 T5 T6 T7 T8 T9 T10
TDEG: -7.0 3.0 13.0 23.0 33.0 43.0 53.0 63.0 73.0 83.0
RSSI: 85 108 126 143 164 169 169 167 117 74
SET SIGNAL STRENGTH TO REFERENCE VALUE
1 SELECT RSSI INDEX S1 - S10
2 READ AND ENTER CALIBRATION VALUE
3 MARK FOR STORAGE IN EEPROM
0. Calibration Menu
Choose alternative: _