Reference Manual

Table Of Contents
FBTEST REFERENCE MANUAL 73 (110)
BRU1/BRU3 MANUAL, Doc.no: b3fb_ref Uen Rev PJ5, 2004-02-19
6.4.10 RSSI Calibration
[Main menu, Radio Operations, Calibration, RSSI Calibration]
Status Line:
Operational conditions
The transmitter and receiver conditions are shown, as described in the
transceiver control and presentation menu. The operation conditions are
changed in Radio Calibration Menu.
Reference values
The measured input signal RSSI, is shown for reference points R1 - R10.
Figure 37 RSSI Calibration menu.
RSSI Calibration SYS:yyyy-mm-dd hh:mm
Current test selection is MEDIUM
TX: OFF TXCH: 3840 PF: 0 TXSEND:OFF RXCH: 3040
RSSI INDEX: 2
T1 T2 T3 T4 T5 T6 T7 T8 T9 T10
TDEG: -7.0 3.0 13.0 23.0 33.0 43.0 53.0 63.0 73.0 83.0
RSSI: 85 108 126 143 164 169 169 167 117 74
SET SIGNAL STRENGTH TO REFERENCE VALUE
1 SELECT RSSI INDEX S1 - S10
2 READ AND ENTER CALIBRATION VALUE
3 MARK FOR STORAGE IN EEPROM
0. Calibration Menu
Choose alternative: _