Reference values
The VCO modulation gain parameters are shown for all temperature index
values.
Alt. 9 SELECT SLOT
Displays SLOT NUMBER [1-3] (1)
34xx:
For each slot the calibration has to be done at three different
frequencies. The frequency band, selected in the “Radio Operation
Parameters in menu” in Figure 23, shall be divided into the current
number of slots. The number of slots is determined by the total
frequency band covered by the BRU3 variant.
38xx and 39xx:
The calibration is done at one frequency.
Enter SLOT NUMBER = 1.
Alt. 10 SELECT SLOT CHANNEL
Displays SLOT CHANNEL (3800)
The SLOT CHANNEL is the upper limit of the channel number for
current slot (slot 1, slot 2 or slot 3)
34xx:
The upper limit for slot 3 shall be set to -1 (=).
38xx and 39xx: