Reference Manual

Table Of Contents
66 (110) BRU1/BRU3 MANUAL
BRU1/BRU3 MANUAL, Doc.no: b3fb_ref Uen Rev PJ5, 2004-02-19
[Main menu, Radio Operations, Calibration, VCO Calibration]
Figure 34 VCO Calibration - 2 menu.
Alt. 1 ENTER TEMPERATURE INDEX T1-T5 FOR OFFSET/
ABSOLUTE MODE
Displays TEMPERATUR INDEX (2)
The temperature index is selected and the temperature check, as
described for temperature calibration, is initiated.
Alt. 2 INCREMENT
Increases the value in steps.
VCO Calibration SYS:yyyy-mm-dd hh:mm
Current test selection is MEDIUM
TX: OFF TXCH: 3840 PF: 0 TXSEND:OFF RXCH: 3040
TEMP INDEX: 2 SLOT: 1 CHANNEL: 3800
T1 T2 T3 T4 T5
TDEG: -8.0 6.0 20.0 34.0 48.0
VCO: 212 201 189 182 179
1 ENTER TEMPERATURE INDEX FOR VCO IN OFFSET/ABSOLUTE MODE
2 INCREMENT3 DECREMENT4 SET VALUE
5 MARK FOR STORAGE IN EEPROM
6 - SELECT TRANSMITTER ON/OFF
7 SELECT MODULATION
8 - SELECT MODULATION ON/OFF
9 SELECT SLOT
10 SELECT SLOT CHANNEL
0. Calibration Menu
Choose alternative: