Reference Manual
Table Of Contents
- FBTEST Reference Manual
- 1 Introduction
- 2 Installation Procedures
- 3 Hardware, Equipment and Preparation
- 4 FBTEST User Modes
- 5 User Interface Description
- 6 Main Menu
- 6.1 Board Test Menu
- 6.1.1 Alt. 1: Do the Test
- 6.1.2 Alt. 2: Number of Test Cycles
- 6.1.3 Alt. 3: Select/Unselect Boards
- 6.1.4 Alt. 4: Select Extended Test
- 6.1.5 Alt. 5: Select Medium Test
- 6.1.6 Alt. 6: Unselect all Tests
- 6.1.7 Alt. 7-11: Sets the Test Parameters for Each Board
- 6.1.8 Alt.7: Set Parameters for FCB–FE Computer Board
- 6.1.9 Alt. 8: Set Parameters for FRB–FE Radio Board
- 6.1.10 Alt. 9: Set Parameters for FNB–FE Connection Board (BRU3 only)
- 6.1.11 Alt. 10 (BRU3): Set Parameters for FMB–FE Modem Board
- 6.1.12 Alt. 10 (BRU1): Set Parameters for FIB - FE Interface Board
- 6.1.13 Alt. 11: Set Params for FPB–FE Power Supply Board (BRU3 only)
- 6.1.14 Alt.12: Look at Test Results
- 6.2 Set Time
- 6.3 Radio Operations
- 6.4 Measurement Setup Menu
- 6.4.1 Transceiver Control and Presentation Menu
- 6.4.2 Radio Calibration Menu
- 6.4.3 Bandgap Calibration
- 6.4.4 Temperature Sensor Calibration
- 6.4.5 Reference Oscillator OCXO Calibration
- 6.4.6 PF Output Power Calibration
- 6.4.7 PR Reflected Power Calibration
- 6.4.8 VCO Modulation Calibration
- 6.4.9 TCXO Modulation Calibration
- 6.4.10 RSSI Calibration
- 6.4.11 EEPROM Display Editor Menu
- 6.4.12 PA Bias and FDAC Calibration Menu
- 6.4.13 Radio Register Editor Menu
- 6.4.14 Adjustment
- 6.4.15 Setup
- 6.5 Modem Operation Menu (BRU3 only)
- 6.6 Interface Board Parameters Menu (BRU1 only)
- 6.7 Status Overview Menu
- 6.8 Edit Loader Parameters Menu (BRU3 and System Release R14 only)
- 6.1 Board Test Menu
64 (110) BRU1/BRU3 MANUAL
BRU1/BRU3 MANUAL, Doc.no: b3fb_ref Uen Rev PJ5, 2004-02-19
If the temperature check was OK these alternatives modify the output reference
value. The measured output power is calibrated to the defined nominal value for
the selected PF index. In offset calibration, all reference values for the selected
PF index are changed.
Alt. 4 MARK FOR STORAGE IN EEPROM
This alternative indicates that this calibration object will be saved in
EEPROM when the calibration procedure is finished.
Alt. 5 SELECT TRANSMITTER ON/OFF
A toggle function between “ + “ (ON) and “ - “ (OFF).
Alt. 6 SLOT NUMBER [1-2]
Displays the selected slot number. Enter the desired slot number
Alt. 7 ATTENUATION [1/10 dB]
Displays the attenuation for the selected slot (1/10 dB) Enter the
desired cable loss in dB for slot 1 and 2 respectively. The slot
number is selected in alternative 6.