FBTEST REFERENCE MANUAL 61 (110)
BRU1/BRU3 MANUAL, Doc.no: b3fb_ref Uen Rev PJ5, 2004-02-19
Operational conditions
The transmitter and receiver conditions are shown, as described in the
transceiver control and presentation menu. The operation conditions are
changed in Radio Calibration Menu.
Alt. 2 ENTER TEMPERATURE INDEX FOR PF IN OFFSET/
ABSOLUTE MODE
Displays TEMPERATURE INDEX (2)
Alt. 3 INCREMENT
Increases the value in steps.
Alt. 4 DECREMENT
Decreases the value in steps.
Alt. 5 SET VALUE
Displays VALUE (x)
The alternatives, if the temperature check was OK, modify the output
reference value. The measured output power on the external
instrument is calibrated to the defined nominal value for the selected
PF index. In offset calibration all reference values for the selected PF
index are changed.
Alt. 6 MARK FOR STORAGE IN EEPROM
This alternative indicates that this calibration object will be saved in
EEPROM when the calibration procedure is finished.
Alt. 7 SELECT TRANSMITTER ON/OFF
A toggle function between “ + “ (ON) and “ - “ (OFF).