Reference Manual

Table Of Contents
FBTEST REFERENCE MANUAL 57 (110)
BRU1/BRU3 MANUAL, Doc.no: b3fb_ref Uen Rev PJ5, 2004-02-19
[Main menu, Radio Operations, Calibration, Reference OCXO Calibration]
Figure 28 Reference Oscillator OCXO Calibration - 2 menu.
Alt. 1 ENTER TEMPERATURE INDEX FOR OCXO IN OFFSET/
ABSOLUTE MODE
Enter TEMPERATURE INDEX (2).
Alt. 2 INCREMENT
Increases the OCXO value in steps.
Alt. 3 DECREMENT
Decreases the OCXO value in steps.
Reference Oscillator OCXO Calibration SYS:yyyy-mm-dd hh:mm
Current test selection is MEDIUM
TX: OFF TXCH: 3840 PF: 0 TXSEND:OFF RXCH: 3040
PF. INDEX: 2 TEMP INDEX: 2
T1 T2 T3 T4 T5
TDEG: -8.0 6.0 20.0 34.0 48.0
OCXO: 80 80 81 81 81
IS OCXO FREQUENCY OK ON EXTERNAL INSTRUMENT ?
1 ENTER TEMPERATURE INDEX FOR OCXO IN OFFSET/ABSOLUTE
MODE
2 INCREMENT3 DECREMENT4 SET VALUE
5 MARK FOR STORAGE IN EEPROM
6 - SELECT TRANSMITTER ON/OFF
0. Calibration Menu