Reference Manual

Table Of Contents
FBTEST REFERENCE MANUAL 55 (110)
BRU1/BRU3 MANUAL, Doc.no: b3fb_ref Uen Rev PJ5, 2004-02-19
[Main menu, Radio Operations, Calibration, Temp. Sensor Calibration. 2]
Figure 26 Temperature Sensor Calibration menu, offset and absolute
mode.
Alt 1. ENTER TEMPERATURE INDEX T1 - T5 FOR OFFSET/
ABSOLUTE MODE
Enter TEMPERATURE INDEX (2):
Alt 2. ENTER CALIBRATION VALUE FOR OFFSET/ABSOLUTE
MODE
Displays whether the temperature is OK or NOT.
Alt. 3 MARK FOR STORAGE IN EEPROM
This alternative indicates that this calibration object will be saved in
EEPROM when the calibration procedure is finished.
Temperature Calibration SYS:yyyy-mm-dd hh:mm
Current test selection is MEDIUM
TX: OFF TXCH: 3840 PF: 0 TXSEND:OFF RXCH: 3040
TEMPERATURE A/D VALUE: 141
TEMPERATURE INDEX: 2
T1 T2 T3 T4 T5
TDEG: -8.0 6.0 20.0 34.0 48.0
TNUM: 78 107 134 163 195
1 ENTER TEMPERATURE INDEX T1 - T5 FOR OFFSET/ABSOLUTE
MODE
2 ENTER CALIBRATION VALUE FOR OFFSET/ABSOLUTE MODE
3 MARK FOR STORAGE IN EEPROM
0. Calibration Menu