52 (110) BRU1/BRU3 MANUAL
BRU1/BRU3 MANUAL, Doc.no: b3fb_ref Uen Rev PJ5, 2004-02-19
6.4.3 Bandgap Calibration
[Main menu, Radio Operations, Calibration, Bandgap Calibration]
The BANDGAP REFERENCE SET VALUE is a digital variable to a DA
converter, which should be set to give a BANDGAP_VOLTAGE of 2.5 V. The
bandgap voltage is not temperature-dependent.
Figure 24 Bandgap Calibration menu.
Alt. 1 INCREMENT
Increases the bandgap by 1 step to 129.
Alt. 2 DECREMENT
Decreases the bandgap by 1 step to 127.
Bandgap Calibration SYS:yyyy-mm-dd hh:mm
Current test selection is MEDIUM
CONNECT VOLTMETER TO BANDGAP VOLTAGE SIGNAL
BANDGAP REFERENCE SET VALUE IS 128 NUM
IS MEASURED VALUE EQUAL TO 2.5 V ?
1 INCREMENT
2 DECREMENT
3 SET VALUE
4 MARK FOR STORAGE IN EEPROM
0. Calibration Menu
Choose alternative: