Reference Manual
Table Of Contents
- FBTEST Reference Manual
- 1 Introduction
- 2 Installation Procedures
- 3 Hardware, Equipment and Preparation
- 4 FBTEST User Modes
- 5 User Interface Description
- 6 Main Menu
- 6.1 Board Test Menu
- 6.1.1 Alt. 1: Do the Test
- 6.1.2 Alt. 2: Number of Test Cycles
- 6.1.3 Alt. 3: Select/Unselect Boards
- 6.1.4 Alt. 4: Select Extended Test
- 6.1.5 Alt. 5: Select Medium Test
- 6.1.6 Alt. 6: Unselect all Tests
- 6.1.7 Alt. 7-11: Sets the Test Parameters for Each Board
- 6.1.8 Alt.7: Set Parameters for FCB–FE Computer Board
- 6.1.9 Alt. 8: Set Parameters for FRB–FE Radio Board
- 6.1.10 Alt. 9: Set Parameters for FNB–FE Connection Board (BRU3 only)
- 6.1.11 Alt. 10 (BRU3): Set Parameters for FMB–FE Modem Board
- 6.1.12 Alt. 10 (BRU1): Set Parameters for FIB - FE Interface Board
- 6.1.13 Alt. 11: Set Params for FPB–FE Power Supply Board (BRU3 only)
- 6.1.14 Alt.12: Look at Test Results
- 6.2 Set Time
- 6.3 Radio Operations
- 6.4 Measurement Setup Menu
- 6.4.1 Transceiver Control and Presentation Menu
- 6.4.2 Radio Calibration Menu
- 6.4.3 Bandgap Calibration
- 6.4.4 Temperature Sensor Calibration
- 6.4.5 Reference Oscillator OCXO Calibration
- 6.4.6 PF Output Power Calibration
- 6.4.7 PR Reflected Power Calibration
- 6.4.8 VCO Modulation Calibration
- 6.4.9 TCXO Modulation Calibration
- 6.4.10 RSSI Calibration
- 6.4.11 EEPROM Display Editor Menu
- 6.4.12 PA Bias and FDAC Calibration Menu
- 6.4.13 Radio Register Editor Menu
- 6.4.14 Adjustment
- 6.4.15 Setup
- 6.5 Modem Operation Menu (BRU3 only)
- 6.6 Interface Board Parameters Menu (BRU1 only)
- 6.7 Status Overview Menu
- 6.8 Edit Loader Parameters Menu (BRU3 and System Release R14 only)
- 6.1 Board Test Menu
FBTEST REFERENCE MANUAL 49 (110)
BRU1/BRU3 MANUAL, Doc.no: b3fb_ref Uen Rev PJ5, 2004-02-19
Operating conditions: TX: OFF TXCH: 3840 PF: 0 TXSEND: OFF RXCH:
3040
The status line, below the header, indicating the present operating conditions for
the transceiver with the following meaning:
• TX is the status of the transmitter, either OFF or ON.
• TXCH or TXFRQ is the transmitter channel frequency or number.
• PF is the transmitter power from 0 to -21 dB in 3 dB steps.
• TXSEND is the transmitter modulation, shown as OFF, NONE, LOW,
HIGH, AC, PRBS or PERIOD. The OFF condition is shown when
modulation is switched off.
• RXCH or RXFRQ is the receiver channel frequency or number.
Measurement data
These measurements that are selected as active, are presented on the following
lines before operator alternatives for control.
• PF VALUE is the measured output power in dB.
• PR VALUE is the measured reflected power in dB.
• RSSI VALUE is the measured receive signal level in dBuVemf.
• TEMPERATURE VALUE is the measured temperature on the radio board
in °C.
• BER RX BITS is the number of received bits, RX ERR is the number of
error bits and finally on this line, two bit error rates are shown as a
percentage. The first value is the quotient (times 100) between the
accumulated number of error bits and the number of received bits. i.e.
100*RX ERR/RX BITS. The second value (within brackets) is the same
quotient, but for the received bits during the latest 1 s. (appr.).
Example:
• ALARM status is shown, with PF_LOW, VSWR and TEMP as YES or NO,
i.e., whether the set limit is exceeded or not.
• RX DEVIATION VALUE is the receive frequency measurement deviation.
+BER Rx BITS: 588765 Rx ERR: 5687 0.966 (0.176)%