Reference Manual
Table Of Contents
- FBTEST Reference Manual
- 1 Introduction
- 2 Installation Procedures
- 3 Hardware, Equipment and Preparation
- 4 FBTEST User Modes
- 5 User Interface Description
- 6 Main Menu
- 6.1 Board Test Menu
- 6.1.1 Alt. 1: Do the Test
- 6.1.2 Alt. 2: Number of Test Cycles
- 6.1.3 Alt. 3: Select/Unselect Boards
- 6.1.4 Alt. 4: Select Extended Test
- 6.1.5 Alt. 5: Select Medium Test
- 6.1.6 Alt. 6: Unselect all Tests
- 6.1.7 Alt. 7-11: Sets the Test Parameters for Each Board
- 6.1.8 Alt.7: Set Parameters for FCB–FE Computer Board
- 6.1.9 Alt. 8: Set Parameters for FRB–FE Radio Board
- 6.1.10 Alt. 9: Set Parameters for FNB–FE Connection Board (BRU3 only)
- 6.1.11 Alt. 10 (BRU3): Set Parameters for FMB–FE Modem Board
- 6.1.12 Alt. 10 (BRU1): Set Parameters for FIB - FE Interface Board
- 6.1.13 Alt. 11: Set Params for FPB–FE Power Supply Board (BRU3 only)
- 6.1.14 Alt.12: Look at Test Results
- 6.2 Set Time
- 6.3 Radio Operations
- 6.4 Measurement Setup Menu
- 6.4.1 Transceiver Control and Presentation Menu
- 6.4.2 Radio Calibration Menu
- 6.4.3 Bandgap Calibration
- 6.4.4 Temperature Sensor Calibration
- 6.4.5 Reference Oscillator OCXO Calibration
- 6.4.6 PF Output Power Calibration
- 6.4.7 PR Reflected Power Calibration
- 6.4.8 VCO Modulation Calibration
- 6.4.9 TCXO Modulation Calibration
- 6.4.10 RSSI Calibration
- 6.4.11 EEPROM Display Editor Menu
- 6.4.12 PA Bias and FDAC Calibration Menu
- 6.4.13 Radio Register Editor Menu
- 6.4.14 Adjustment
- 6.4.15 Setup
- 6.5 Modem Operation Menu (BRU3 only)
- 6.6 Interface Board Parameters Menu (BRU1 only)
- 6.7 Status Overview Menu
- 6.8 Edit Loader Parameters Menu (BRU3 and System Release R14 only)
- 6.1 Board Test Menu
FBTEST REFERENCE MANUAL 19 (110)
BRU1/BRU3 MANUAL, Doc.no: b3fb_ref Uen Rev PJ5, 2004-02-19
The selected alternative will display other menus as follows:
Using the Exit alternative exists the FBTEST program and the node will be
restarted.
The second line from the top of the screen tells the user which test selection has
been chosen. The test alternatives are Medium, Extended, No-tests or User-
defined. Medium is default.
Alt. 1 BOARD TEST
Displays the Board Test menu, Figure 3 for BRU3 and Figure 4 for
BRU1.
Alt. 2 SET TIME
Displays the Set System Clock menu, Figure 17.
Alt. 3 RADIO OPERATIONS
Displays the Radio Control and Calibration menu, Figure 18.
Alt. 4
(BRU3)
MODEM OPERATIONS
Displays the Modem Operation menu, Figure 47.
Alt. 4
(BRU1)
INTERFACE BOARD
Displays the Interface Board (for BRU1 only), Figure 48.
Alt. 5 STATUS OVERVIEW
Displays the Status Overview menu, Figure 50for BRU3 and Figure
51 for BRU1.
Alt. 6
(BRU3)
EDIT LOADER PARAMETERS
Displays the Edit Loader Parameters, Figure 52.