Reference Manual
Table Of Contents
- FBTEST Reference Manual
- 1 Introduction
- 2 Installation Procedures
- 3 Hardware, Equipment and Preparation
- 4 FBTEST User Modes
- 5 User Interface Description
- 6 Main Menu
- 6.1 Board Test Menu
- 6.1.1 Alt. 1: Do the Test
- 6.1.2 Alt. 2: Number of Test Cycles
- 6.1.3 Alt. 3: Select/Unselect Boards
- 6.1.4 Alt. 4: Select Extended Test
- 6.1.5 Alt. 5: Select Medium Test
- 6.1.6 Alt. 6: Unselect all Tests
- 6.1.7 Alt. 7-11: Sets the Test Parameters for Each Board
- 6.1.8 Alt.7: Set Parameters for FCB–FE Computer Board
- 6.1.9 Alt. 8: Set Parameters for FRB–FE Radio Board
- 6.1.10 Alt. 9: Set Parameters for FNB–FE Connection Board (BRU3 only)
- 6.1.11 Alt. 10 (BRU3): Set Parameters for FMB–FE Modem Board
- 6.1.12 Alt. 10 (BRU1): Set Parameters for FIB - FE Interface Board
- 6.1.13 Alt. 11: Set Params for FPB–FE Power Supply Board (BRU3 only)
- 6.1.14 Alt.12: Look at Test Results
- 6.2 Set Time
- 6.3 Radio Operations
- 6.4 Measurement Setup Menu
- 6.4.1 Transceiver Control and Presentation Menu
- 6.4.2 Radio Calibration Menu
- 6.4.3 Bandgap Calibration
- 6.4.4 Temperature Sensor Calibration
- 6.4.5 Reference Oscillator OCXO Calibration
- 6.4.6 PF Output Power Calibration
- 6.4.7 PR Reflected Power Calibration
- 6.4.8 VCO Modulation Calibration
- 6.4.9 TCXO Modulation Calibration
- 6.4.10 RSSI Calibration
- 6.4.11 EEPROM Display Editor Menu
- 6.4.12 PA Bias and FDAC Calibration Menu
- 6.4.13 Radio Register Editor Menu
- 6.4.14 Adjustment
- 6.4.15 Setup
- 6.5 Modem Operation Menu (BRU3 only)
- 6.6 Interface Board Parameters Menu (BRU1 only)
- 6.7 Status Overview Menu
- 6.8 Edit Loader Parameters Menu (BRU3 and System Release R14 only)
- 6.1 Board Test Menu
FBTEST REFERENCE MANUAL 11 (110)
BRU1/BRU3 MANUAL, Doc.no: b3fb_ref Uen Rev PJ5, 2004-02-19
3 Hardware, Equipment and Preparation
The preparation work necessary for testing a node is kept at a minimum. A
console terminal has to be attached to the Console Connector on the node, and
if a test that requires external hardware is to be executed, special test cables are
to be connected.
3.1 Configuration
All terminal inputs and outputs are directed to the console. The console should
be a VT100 terminal or the equivalent.
The communication parameters should be as follows:
• Baud rate 9600.
• 8 data bits.
• no parity.
Most VT100-compatible terminals feature dumping the screen information to a
hardcopy device, which may be very useful when logging the results from the
tests. See the documentation of the actual terminal for more information.