Reference Manual
Table Of Contents
- FBTEST Reference Manual
- 1 Introduction
- 2 Installation Procedures
- 3 Hardware, Equipment and Preparation
- 4 FBTEST User Modes
- 5 User Interface Description
- 6 Main Menu
- 6.1 Board Test Menu
- 6.1.1 Alt. 1: Do the Test
- 6.1.2 Alt. 2: Number of Test Cycles
- 6.1.3 Alt. 3: Select/Unselect Boards
- 6.1.4 Alt. 4: Select Extended Test
- 6.1.5 Alt. 5: Select Medium Test
- 6.1.6 Alt. 6: Unselect all Tests
- 6.1.7 Alt. 7-11: Sets the Test Parameters for Each Board
- 6.1.8 Alt.7: Set Parameters for FCB–FE Computer Board
- 6.1.9 Alt. 8: Set Parameters for FRB–FE Radio Board
- 6.1.10 Alt. 9: Set Parameters for FNB–FE Connection Board (BRU3 only)
- 6.1.11 Alt. 10 (BRU3): Set Parameters for FMB–FE Modem Board
- 6.1.12 Alt. 10 (BRU1): Set Parameters for FIB - FE Interface Board
- 6.1.13 Alt. 11: Set Params for FPB–FE Power Supply Board (BRU3 only)
- 6.1.14 Alt.12: Look at Test Results
- 6.2 Set Time
- 6.3 Radio Operations
- 6.4 Measurement Setup Menu
- 6.4.1 Transceiver Control and Presentation Menu
- 6.4.2 Radio Calibration Menu
- 6.4.3 Bandgap Calibration
- 6.4.4 Temperature Sensor Calibration
- 6.4.5 Reference Oscillator OCXO Calibration
- 6.4.6 PF Output Power Calibration
- 6.4.7 PR Reflected Power Calibration
- 6.4.8 VCO Modulation Calibration
- 6.4.9 TCXO Modulation Calibration
- 6.4.10 RSSI Calibration
- 6.4.11 EEPROM Display Editor Menu
- 6.4.12 PA Bias and FDAC Calibration Menu
- 6.4.13 Radio Register Editor Menu
- 6.4.14 Adjustment
- 6.4.15 Setup
- 6.5 Modem Operation Menu (BRU3 only)
- 6.6 Interface Board Parameters Menu (BRU1 only)
- 6.7 Status Overview Menu
- 6.8 Edit Loader Parameters Menu (BRU3 and System Release R14 only)
- 6.1 Board Test Menu
FBTEST REFERENCE MANUAL 107 (110)
BRU1/BRU3 MANUAL, Doc.no: b3fb_ref Uen Rev PJ5, 2004-02-19
6.8.4 Read Parameters from FLASH
[Main menu, Edit Loader Parameters, Read Parameters from FLASH]
Note: Alternative 6 should now be selected! If alternative 5 is selected,
the result will be that the newly entered or modified parameter
values will be overwritten by the values stored in the Flash
PROM.
Figure 64 Edit Loader Parameters menu - selection of parameters.
Alt 1. Enter your own node number [0 - 9999]: (xxxxx)
Alt 2. Gives the menu in Figure 54.
Alt 3. Gives the menu in Figure 60.
Alt 4. Gives the menu in Figure 65.
Alt 5. Reads the parameters from Flash.
Alt 6. Stores the parameters in Flash.
Edit loader parameters SYS:yyyy-mm-dd hh:mm
Current test selection is MEDIUM
1 Node XXXXX
2 Ports
3 Channels
4 Connections
5 Read parameters from Flash
6 Store parameters to Flash
0. Main menu
Choose alternative: