Reference Manual

Table Of Contents
104 (110) BRU1/BRU3 MANUAL
BRU1/BRU3 MANUAL, Doc.no: b3fb_ref Uen Rev PJ5, 2004-02-19
[Main menu, Edit Loader Parameters, Channels, X.25 Parameters]
Figure 61 X.25 Parameters for Channel 1 menu.
Alt 1. Enter the Remote address: The Address for the MOX.
Alt 2. Enter Packet size [-1 - 512]:(128)
Alt 3. Enter Window size [-1 - 7]:(2)
Alt 4. Enter the Connection type:
A toggle function between VC and PVC type.
Alt 5. VC - mode:
Not alterable in VC-mode. Press any key to continue:
PVC - mode:
LOGCHAN [1 - 4095]:(1)
Alt 6-8 A toggle function between YES and NO.
X.25 parameters for channel 1 SYS:yyyy-mm-dd hh:mm
Current test selection is MEDIUM
1. Remote address : 00000
2. Packet size : 128
3. Window size : 2
4. Connection type : VC
5. Logical channel : -1
6. Request rev chg : No
7. Accept rev chg : Yes
8. Accept empty addr : No
0. Previous menu
Choose alternative: _