Specifications

Integration Technical Note 11
NEC NEAX 2000/2400 MCI ©June 2003 Ericsson Enterprise AB
EN/LZT 108 6656 R1A
3. Command Code CM15: Modify the OneBox Service Class Restriction group
that was programmed in CM12. It is not necessary to change default settings
other than those listed in Table 4.
ST+15YY/YYY+DE+SERVICE RESTRICTION CLASS A/B/C
(00-15)+DE+DATA (1 digit)+EXE
Table 4. Service Class Restriction Data for OneBox Ports
First
Data
Description
Second
Data
Value
09 Exec Override 0 Restrict
22 Trunk to trunk transfer
(see Note 1)
0 Restrict
24 MW reset from other stn. 0 Restrict
30 Account Code 0 Restrict
31 Authorization Code 0 Restrict
97 UCD Call Waiting 0 Restrict
98 UCD Call Waiting 1 Restrict
103 Call Monitoring 0 Restrict
104 Call Monitoring 0 Restrict
Note 1. Some applications may require trunk-to-trunk transfers.
This capability can be a security risk for the customer.
4. Command CM13: Assign VMS attributes to OneBox stations.
ST+1303+DE+STATION NUMBER+DE+0+EXE
(Provide MW service for a station with a MW lamp)
ST+1304+DE+STATION NUMBER+DE+0+EXE
(Disable Howler tone)
ST+1310+DE+STATION NUMBER+DE+0+EXE
(Enable as VMS Station)
ST+1322+DE+STATION NUMBER+DE+0+EXE
(Provide momentary open on disconnect)
See Command Code CM41 function 08 for Momentary Open timer
duration. The timer default is 256–384ms. The OneBox default for loop-
current disconnect is 100ms.