Specifications

Integration Technical Note 9
NEC NEAX 2000/2400 MCI ©June 2003 Ericsson Enterprise AB
EN/LZT 108 6656 R1A
Data Programming for MCI
Use the commands listed below to program and define the MCI data port for
VMS.
1. Command Code CM08:
ST+08+DE+025+DE+0+EXE (Provide MSG display message)
ST+08+DE+443+DE+0+EXE (Provide VMS with MCI)
ST+08+DE+444+DE+0+EXE (Provide MW control from VMS with MCI)
ST+08+DE+376+DE+0+EXE (Provide MW over CCIS if used)
2. Command Code CM90. Assign the data to provide the MW lamp on a D
term
,
if required.
ST+9000+DE+My Line No. +,+Key No. DE+F1005+EXE
3. Command Code CMD000: Specify whether the message-waiting control text
is sent to OneBox when the PN-AP00 is reset.
ST+D000+DE+136+DE+0+EXE (To send)
4. Command Code CMD000: Specify the number of digits for the station
number in the message format.
ST+D000+DE+137+DE+0+EXE (0=6 digits, 1=8 digits)
5. Command Code CMD000: Specify whether the MCI port will be port 3 on
the PN-AP00.
ST+D000+DE+138+DE+0+EXE (not to provide)
6. Command Code CM35. Provide sending of the ANI information from the
network to the VMS with MCI.
ST+35+DE+138+DE+0+EXE (0=send ANI, 1=do not send ANI)
7. Command Code CMD001. Specify the message format sent to the VMS with
MCI as Conventional or Expanded (with ANI) format.
ST+D001+DE+36+DE+1+EXE (0=Conventional, 1=Expanded)
8. Command Code CMD001: Assign the attribute data to the port that will be
used as the VMS port. Table 3 shows the data parameters to assign. This
table uses port 0 with port attribute settings of 9600, 8, N, and 1 as an
example.
ST+D001+DE+1
st
DATA+DE+2
nd
DATA+EXE