Specifications
Integration Technical Note 7
NEC NEAX 2000/2400 MCI ©June 2003 Ericsson Enterprise AB
EN/LZT 108 6656 R1A
•
One loop-start station for each OneBox port to be configured
Use 16LCQ or 16LCBE cards, or their equivalent, because of their ability to
provide open loop-current disconnect signaling. The LCQ card provides a
fixed 128-194 ms. open on disconnect and the LCBE card has a
programmable open loop duration.
OR
• A PA-24DTR digital trunk interface configured as T1 loop-start stations,
which will provide up to 24 channels to OneBox. Configure this board for
D4 (SF), AMI, ABAB
OneBox Requirements
• A properly configured Microsoft Windows 2000 Server Service Pack 2
telephony server platform with an available serial port
• OneBox UM software version 3.0 or later
• Ericsson software key diskette with NEC NEAX 2000 or NEC NEAX 2400
MCI serial integration enabled
• One Dialogic port for each OneBox voice port to be integrated
• Uninterruptible power supply (UPS) and surge protection device
(recommended)