2.5.6  Technical Earth 
The unit has a Technical earth terminal (marked with ) located at the rear panel 
(see Figure 2.5). Its use is recommended. This is NOT a Protective earth for electric 
shock protection. The terminal is provided to: 
•  Ensure all equipment chassis fixed within a rack are at the same Technical earth 
potential. To do this, connect a wire between the Technical earth terminal and a 
suitable point on the rack. 
•  Eliminate the migration of stray charges when connecting between equipment. 
Warning! 
If the terminal screw has to be replaced, use the following: 
M3 x 12 mm long Pozidrive Panhead. 
Using a longer screw may cause a safety hazard. 
2.6  Signal Connections 
2.6.1  Introduction 
All signal connectors are located at the rear panel of the unit. For a detailed 
interface specification see Annex B, Technical Specification. 
Always use the specified cables supplied for signal integrity and compliance with 
EMC requirements (see Annex B, Technical Specification). 