User guide
  Technical Specification
Parameter Range  Default value 
Modulation configuration. Parameters to be used to configure all Modulated outputs. 
Mode  Annex A Annex B Annex C  Annex A 
  Annex A  Annex B  Annex C  Annex A  Annex B  Annex C 
Constellation 64QAM 
256QAM 
64QAM 
256QAM 
64QAM 
256QAM 
64QAM 64QAM  64QAM 
Symbol Rate 
(MSym/s) with 
resolution of 
1 symbol/sec 
Fixed Fixed Fixed 6.952 
64QAM: 
5.056941 
256QAM: 
5.360537 
64QAM: 
5.350 
256QAM: 
5.350 
Interleaving Depth (I,J) 
(12,17) 
(Fixed) 
(128,1) 
(64,2) 
(32,4) 
(16,8) 
(8,16) 
(128,2) 
(128,3) 
(128,4) 
(128,5) 
(128,6) 
(128,7) 
(128,8) 
(12,17) 
(Fixed) 
(12,17) (64,2)  (12,17) 
Centre RF output 
frequency for 
carrier 1 (MHz) 
with resolution of 
10 kHz 
57-855 (996 
when 1GHz 
license 
enabled) 
57 
RF output level 
(dBmv) with 
resolution of 
0.1 dBmV 
44..58 44 
Channel number  1..4  1..4 
Channel mode 
(RF output 
status) 
ON 
OFF 
Test 
Dual Tone 
OFF 
RF Output 
Configuration. 
An entry for each RF 
connector (3) 
ENABLED, 
DISABLED 
ENABLED 
Software watchdog 
reset 
ENABLED, DISABLED  DISABLED 
Activate Unit reset     
2/1553-FGC 101 1019 Uen A   
B-9