  Introduction to the EQ8096
•  The RF channel that each TS is multiplexed to is defined in Table 1.3. 
•  The EQ8096 can optionally be controlled via an ERM/SDV server using RPC 
control protocol. 
1.2.3  Transport Stream Processing 
The EQ8096 is designed to automatically detect incoming Transport Streams and 
remultiplex them into new multi-program Transport Streams. 
•  Each service has its PCR recovered and re-stamped after Multiplexing into the 
output MPTS (QAM). The subsequent absolute bit rate of the output stream will 
be within +/- 30 ppm of the originating stream. The rate of change of bit rate of 
each multiplexed service is within the MPEG-2 system specification. 
1.2.4  PSI Extraction and Insertion 
The unit carries out automatic PSI extraction (PAT and PMTs referenced in the 
PAT) from each of the incoming TS flows. While the unit remains locked to the 
incoming flow it periodically monitors the incoming transport stream for changes in 
the PAT or PMT. 
The PIDs extracted from these tables are used to configure the PID filters for each 
of the flows. Each PID filter supports the filtering and remapping of up to 16 
elementary streams. These are extracted sequentially from the PMT. A single SPTS 
will occupy 1 PID filter. For MPTS, single services within occupy 1 PID filter, thus 
allowing any MPEG service to convey up to 16 elementary streams. The EQ8096 
does not support extraction of tables other than the PAT and PMT. 
For each generated multiplexed transport stream, the EQ8096 generates a PAT and 
series of PMTs that reflect the make up of the transport stream. Any descriptors 
extracted from the incoming flow are transferred to the appropriate PMT. 
The user can define the PID ranges to be used for the PMTs, elementary streams 
and ECMs. 
1.2.5  DOCSIS 3.0 DTI Timestamping 
When a channel is being operated as a DEPI data device, the unit will automatically 
adjust or insert time stamps based on the current unit running Time stamp. The 
optional DTI client card translates DTI time stamps from the DTI server and provides 
DTI lock to the EQ8096 unit. This frequency lock is used to stamp or insert 
(depending on DEPI PSP or MPT mode) DEPI SYNC packets as they transit 
through the box. 
2/1553-FGC 101 1019 Uen A 
1-7