User guide
  Upgrading EQ8096 with Input and Output Option Cards
9.3.4  Restore Unit IP and Serial Number 
The original Serial number, IP address and Configuration must be applied to the 
new Input card. 
To restore this information: 
1.  Power on the EQ8096, making sure all the steps above have been performed 
correctly. 
2.  Using the RS-232 port on the rear panel of the input card, connect to a PC at 
115,200 baud, 8, n, 1, n and ensure that you have the ‘Monitor>’ prompt. 
3.  Type ‘sn <original serial number>’ to set the unit’s serial number. 
4.  Type ‘ip3 <original IP address>’ to set the unit’s main control port address 
(alternatively the IP address can be set from the Front Panel as described in the 
Reference Guide). 
5.  Power cycle the unit. 
9.3.5  Reconfigure the Unit 
To verify that the cards are recognized by the unit: 
1.  Power up the unit and, using a web browser such as Internet Explorer, navigate 
to the EQ8096 home page by entering the IP address set in the previous step 
into the browser's address field and check that the GUI responds. 
2.  Check using the GUI that it recognises the fitted PCB cards and no faults are 
seen. Check also the IP address and Serial number are correctly reported, as 
per the instructions in 7.1 
To reload the original configuration into Flash: 
1.  FTP into the unit as outlined in section 7.1, making sure that your source 
directory contains the ‘config.xml’ file obtained originally. 
2.  Type ‘put config.xml config’ 
3.  After the transfer has completed type ‘bye’ to exit the FTP session. 
4.  Check that the unit has been correctly configured, as per the original unit 
configuration. 
2/1553-FGC 101 1019 Uen A 
9-9










