  Upgrading EQ8096 with Input and Output Option Cards
9.1  Introduction 
This document defines the procedures installing and removing Input and Output 
Option Cards. 
9.1.1  Responsibilities 
The operator should be capable to working to IPC-A-610 standards and follow 
precautions set down in P035 Handling and Protection of ESD product. 
In case of problems please contact customer services. 
9.1.2  Tools Required 
The following tools are required for installation and removal: 
2 x S14483 Card Extraction Tools 
9.1.3  Parts Required 
The procedures given in this chapter refer to installation and replacement of the 
parts listed in the following table 
Table 9.1  Parts Required 
Part Number  Qty  Description 
EQ8096/HWO/12QAM  A/R  12QAM Output Card 
EQ8096/HWO/IP-RJ45  A/R  Input Card with RJ-45 Connections 
EQ8096/HWO/IP-SFP  A/R  Input Card with SFP Connections 
9.2  Installing/Removing a 12QAM Output Card 
When installing or removing the 12QAM Output Card from the EQ8096 Edge QAM, 
the following process should be used. 
9.2.1  Preparing the Unit 
Before installing an Output Card the EQ8096 should be prepared, as follows: 
1. Refer to Chapter 2, Installing the Equipment for slot numbering and assignment 
information 
2.  Ensure the unit is disconnected from the AC or DC mains. 
3.  Maintain ESD precautions. 
2/1553-FGC 101 1019 Uen A 
9-3