ASI Option Module Alarms 
The following table lists the alarm and failure identifiers generated by the ASI option module. 
metadata  Module  Slot n
0  000A00B5
655541
input  stop encoding on loss. 
Name 
Module  Slot  Port
ID (hex)  ID (dec)
Type  Description 
Over Temperature 
Warning 
ASI IO 
Module 
Slot 1
0  000E0001
917505  internal
Failure to take action may cause 
permanent damage to the chassis. Please 
check the fans are working correctly, and 
that th eambient temperature is not 
excessive. 
Over Temperature
ASI IO 
Module 
Slot 1
0  000E0002
917506  internal
Failure to take action may cause 
permanent damage to the chassis. Please 
switch off and refer to Customer Support. 
Invalid Parameter
ASI IO 
Module 
Slot 1
0  000E0003
917507  internal
Invalid Parameter received by the ASI IO 
Module. Please see Video Encoder status 
for a more detailed description of the error.
 Module Error 
ASI IO 
Module 
Slot 1
0  000E0004
917508  internal
Option Card Error. Please see log for a 
more detailed description of the error. 
Power On Self 
Test Failure 
ASI IO 
Module 
Slot 1
0  000E0006
917510  internal
At least one start-up test has failed. 
Problems may be experienced with the 
normal operation of the chassis. 
Internal HW 
Information 
ASI IO 
Module 
Slot 1
0  000E0007
917511  internal
HW reported an unexpected status value. 
This does not effect normal operation of 
the chassis. 
Option Card Build 
Version Mismatch 
ASI IO 
Module 
Slot 1
0  000E0008
917512  internal
The software on this option card is not an 
officially released version. 
ASI Output Error 
ASI IO 
Module 
Slot 1
0  00110020
1114144
internal
An error has occurred in ASI Output 1. See 
the log for more details. 