Operating instructions
HD H.264 VCM Alarms - EN8190 
The following table lists the alarm and failure identifiers generated by the HD H.264 VCM. 
HD H.264 Pre-Processor Module 
Referenced Output Stream 
Unavailable 
Base Unit
Slot 1 to Slot 6
0  00000461
1121  internal
card is not 
installed in 
the specified 
slot or it 
cannot 
provide the 
requested 
output 
stream. 
Name 
Module  Slot  Port
ID (hex)  ID (dec)
Type  Description 
Over Temperature 
Warning 
EN8190 Pre-
Processor 
Module 
Slot 3
0  000C0001
786433
internal
Failure to take action may cause 
permanent damage to the chassis. 
Please check the fans are working 
correctly, and that th eambient 
temperature is not excessive. 
Over Temperature
EN8190 Pre-
Processor 
Module 
Slot 3
0  000C0002
786434
internal
Failure to take action may cause 
permanent damage to the chassis. 
Please switch off and refer to 
Customer Support. 
Invalid Parameter
EN8190 Pre-
Processor 
Module 
Slot 3
0  000C0003
786435
internal
Invalid Parameter received by the 
Video/Audio Module. Please see Video 
Encoder status for a more detailed 
description of the error. 
Video/Audio 
Module Error 
EN8190 Pre-
Processor 
Module 
Slot 3
0  000C0004
786436
internal
Video/Audio Module Error. Please see 
Video Encoder status for a more 
detailed description of the error. 
Power On Self 
Test Failure 
EN8190 Pre-
Processor 
Module 
Slot 3
0  000C0006
786438
internal
At least one start-up test has failed. 
Problems may be experienced with the 
normal operation of the chassis. 
Internal HW 
Information 
EN8190 Pre-
Processor 
Module 
Slot 3
0  000C0007
786439
internal
HW reported an unexpected status 
value. This does not effect normal 
operation of the chassis. 
Option Card Build 
Version Mismatch 
EN8190 Pre-
Processor 
Module 
Slot 3
0  000C0008
786440
internal
The software on this option card is not 
an officially released version. 
SMPTE334 Closed 
Captions Input 
Lock 
EN8190 Pre-
Processor 
Module 
Slot 3
1  000C0009
786441
input 
No valid SMPTE334 Closed Captions 
can be detected 
Video Processor 
Boot Failure 
EN8190 Pre-
Processor 
Module 
Slot 3
1  000C0010
786448
internal
At least one video processor has not 
booted 
Video Processor 
Alive Count 
Failure 
EN8190 Pre-
Processor 
Module 
Slot 3
1  000C0011
786449
internal
At least one video processor has not 
incremented its alive count 
Timecode Locked 
EN8190 Pre-
Processor 
Module 
Slot 3
1  000C0012
786450
input 
Timecode extraction is on but no 
timecode is present 
Video Input Lock 
EN8190 Pre-
Processor 
Module 
Slot 3 
1  000C0005
786437
input 
No valid video found on video input. 
Please check source connection. 
Audio1 DD Pass 
Thru sync loss 
Audio Module
Slot 3
0  000C0041
786497
input 
Audio and Video were not locked prior 
to encoder input. 
Audio1 Input Lock
Audio Module
Slot 3
0  000C0042
786498
input 
No valid audio found on selected input. 
© Ericsson AB 2011. All rights reserved 
Page 
148
 of 
153
Cover
9/11/2012
file://C:\Users\ebriacl\AppData\Local\Temp\~hh7DF.htm