User guide
  Operating the Multiplexer using nCompass Control
The nCompass Control is required to configure the MX8400. Monitoring can be 
done using nCompass Equipment Status. 
4.3  Connecting the MX8400 Multiplexer 
To test connectivity to the MX8400 Multiplexer (once the IP address has been set), 
connect it to a PC using one of the Control ports, and use the PING command. 
Once IP connectivity has been established all other configuration is achieved using 
nCompass Control. 
1.  Run nCompass Control's Equipment Setup GUI 
2.  Open a new map 
3.  Right click and select Add device -> Mux 
4.  Enter the MX8400's IP address and click "Get Static Parameters" 
5.  This will allow you to configure all the static parameters on the unit (see Annex C 
for the use of static parameters) 
6.  The dynamic parameters are all configured using nCompass Control's Profile 
Manager 
For further details, refer to the nCompass Control manual. 
4.4  Configuring the MX8400 Multiplexer 
4.4.1  Definition 
In the context of this Reference Guide, Operating the Equipment Remotely refers to 
the MX8400 Multiplexer in conjunction with nCompass Control. This is where the 
customer operates a system requiring scheduled changes to the bit rates and 
configurations. 
Using this mode of operation, system and associated parameters are constructed in 
the nCompass Control and downloaded to the MX8400 on completion or to a timed 
schedule. 
4.4.2  nCompass Control Functions 
nCompass Control provides a centralized control function for the Ericsson 
multichannel range of equipment. In particular, it provides the following facilities: 
•  Configuration of Encoders, Modulators, Routers and Multiplexers over an 
Ethernet link. 
2/1553-FGC 101 1014 Uen B 
4-5