User guide
ProMPEG FEC Support for IP Streaming   
G.3  Configuration of ProMPEG FEC Outputs 
G.3.1  ProMPEG FEC Mode 
When ProMPEG FEC is enabled this setting allows the IP output to be configured to 
work in FEC Column only mode or FEC Row and Column mode. 
When either of these settings is selected the MPEG transport stream is set to 
operate in RTP mode. 
If FEC Column only mode is selected, a FEC stream is sent out on the same IP 
address as the MPEG transport stream, but on the UDP destination port number two 
higher than the MPEG transport stream. 
If FEC Row and Column mode is selected, two FEC streams are sent out on the 
same IP address as the MPEG transport stream. The column FEC stream is sent 
out on the UDP destination port number two higher then the MPEG transport 
stream, and the row FEC stream is sent out on the UDP destination port four higher 
than the MPEG transport stream. 
G.3.2  Number of Columns (L) Option 
This setting configures the number of columns in the matrix, and determines the 
number of MPEG packets used when calculating the row FEC packets. 
G.3.3  Number of Rows (D) Option 
This setting configures the number of rows in the matrix, and determines the number 
of MPEG packets used when calculating the column FEC packets. 
G.3.4  ProMPEG FEC Constraints 
G.3.4.1  Matrix Limitations in Columns only mode: 
L * D ≤ 100 
1 ≤ L ≤ 20 
4 ≤ D ≤ 20 
G.3.4.2  Matrix Limitations in Rows and Columns mode: 
L * D ≤ 100 
4 ≤ L ≤ 20 
4 ≤ D ≤ 20 
  2/1553-FGC 101 1014 Uen B 
G-4 