User's Manual

Open Information
DESCRIPTION 8 ( 12 )
EIN/R/I Maude Andersson 1/1553-COH 109 334/1 Uen
ERA/RGG/THC 2002-05-31 B
Prepared (also subject responsible if other) No
Approved Checked Date Rev Reference
E
Relative humidity
5% to 85% 5% to 90% 5% to 90%
Absolute
humidity
1 g/m³ to 25 g/m³ less than 25 g/m³ less than 25 g/m³
Table 4 Nominal and Maximum Heat Generation by Configuration
Configuration
Average Heat
Generation
Maximum Heat
Generation
3×1
1.6 kW 2.3 kW
1.5 Connection Interfaces
This section provides information about the interfaces to the RBS 3202.
The CF, plus the interfaces for grounding, power, and antennas, are located on
the RBS 3202 cabinet top. The top of the cabinet is shown in figure 6.
The CF is used as the interface to the cabinet boards. The CF contains the
interfaces for transmission, local Operation and Maintenance (O&M) and
Auxiliary Unit Hub (AU-Hub).
Figure 6 Interfaces
The following interfaces are described in this section (the numbers in the list
coordinate with the numbers in figure 6):
1 Grounding interfaces (chapter 1.5.1)
2 Power interface (chapter 1.5.2)
3 Antenna interfaces (chapter 1.5.3)
4 Transmission interface, ET-M1 (chapter 1.5.4)
5 Transmission interface, ET-M4 (chapter 1.5.4)
6 SiteLAN interface including local Operation and Maintenance (O&M)
(chapter 1.5.5)
7 AU-Hub interface (chapter 1.5.6)
8 Transmission Adapter
1.5.1 Grounding Connection Interface
figure 7 shows the grounding connection interface for the RBS 3202.