User's Manual

Limited Internal
CONFIGURATION DATA 8 ( 11 )
EIN/R/I Anders Larsson 1/1551-COH 109 334/1 Uen
ERA/RGG/TOC Jan Lundkvist 2002-06-03 A
Prepared (also subject responsible if other) No
Approved Checked Date Rev Reference
E
Table 5 HW Units (3*1 Configuration)
HW Unit No. of Units Comments
SCB
1
GPB
1
TUB
1
BBIFB
1
ETB-M1
0–4
ETB-M4
0–2
Total 1–6 ETBs
RAXB Min 3
Max 5
TXB
1
RFIFB
1
TRXB
3
AIU
3
MCPA
3
MCPA-hub
1
2.3.1 Power Requirements
The power requirement for the RBS 3202 is nominal –48V, with 150A fuse.
Operational voltage is between –40,5 V DC and –57,0 V DC.
Tabl e 6
Configuration Nominal Power
Consumption
Maximum Power
Consumption
3x1
1.6 kW 2.3 kW
3 Transmission Guidelines RBS 3202
Transmission Connection Interface is shown infigure 4.
Figure 4 Transmission Connection Interface with MiniWift