Reference Manual
Radio Configurations, RBS 2106 and RBS 2206
M = Mandatory
SCC 1 x 2 and 2 x 2 can be achieved as a subset of SCC 3 x 2.
SCC 1 x 2 requires one CDU-G.
SCC 2 x 2 requires two CDU-Gs.
SPB with CDU-G Configurations with Hybrid Combiner
The following SCC supports SPB. The basic radio configurations
specified are used. SW power boost can be used in cells that have two
dTRUs installed.
Table 38 CDU-G configurations with hybrid combiner
SCC
Configuration TMA Number of
Antennas
Allowed Number of dTRUs
3x4 3 x G8dht_2.4 M (2) (2) (2) (0..2) (0..2) (0..2)
3 x G9deht_2.4 M (2) (2) (2) (0..2) (0..2) (0..2)
3 x G18dht_2.4 M (2) (2) (2) (0..2) (0..2) (0..2)
3 x G19dht_2.4 M (2) (2) (2) (0..2) (0..2) (0..2)
M = Mandatory
Each sector is split into two cells:
• one underlaid cell consisting of the second TRX in the first dTRU
and the first TRX in the second dTRU. SPB is used in this cell.
•
one overlaid cell consisting of the two other TRXs. SPB is not
used in this cell.
4.7 Co-Siting with RBS 200 or RBS 2000 Macro Cabinets
This section shows expansions where RBSs, forming an original SCC,
are co-sited and use TG-synchronization to form one new resulting
SCC. Antennas are not shared.
78 (485)
EN/LZT 720 0008 P2A
2001-11-28
© Ericsson Radio Systems AB
— All Rights Reserved —
Preliminary