EMC Capabilities
Table 174 Surge test 1.2/50 pulses
Limit standard EN 61000-4-5
Test level 2 kV common mode between line and cabinet ground reference
1 kV differential mode between line and line
Performance Criteria B for a complete system
Criteria TT for transmitter units
Criteria TR for receiver units
Table 175 Surge test 10/700 pulses
Limit standard EN 61000-4-5
Test level 1 kV common mode between line and cabinet ground reference
1 kV differential mode between line and line
Performance Criteria B for a complete system
Criteria TT for transmitter units
Criteria TR for receiver units
Table 176 Power induction test
Basic standard ITU-T K.20
Test level 600 V(rms) common mode
Performance Criteria A(K.20)
Table 177 RF common mode test
Limit standard ETS 300 342-2
Test level 10 V(rms)
Performance Criteria A for a complete system
Criteria CT for transmitter units
Criteria CR for receiver units
52.3.7 Radiated Immunity of Enclosure Port
Table 178 Immunity of continuous electric fields
Basic standard IEC 801-3
Test level 10 V/m
Performance Criteria A
Limit standard ETS 300 342-2
Test level 10 V/m, 80 MHz - 1 GHz
Frequency range 30 V/m, 1 GHz-20 GHz
Performance Criteria A for a complete system
EN/LZT 720 0008 P2A
2001-11-28
409 (485)
© Ericsson Radio Systems AB
All Rights Reserved
Preliminary