Reference Manual
Unit Description, TMA-CM
11.4 Indicators
The TMA-CM has eight indicators on the front panel that shows the
status of each TMA and the status of the TMA-CM.
The indicators Fault and Operational indicate the status of the
TMA-CM only, not the status of the TMAs.
Table 98 Indicators
Indicator
Colour
Fault Red
Operational Green
TMA1 in operation
Green
TMA2 in operation
Green
TMA3 in operation
Green
TMA4 in operation
Green
TMA5 in operation
Green
TMA6 in operation
Green
11.5 Electrical Data
11.5.1 Input Data
Table 99 Input data
Nominal input voltage
+24 V DC
Input voltage range
+20.0 to +29.5 V DC
Non-destructive voltage 0 to +32 V DC
Maximum input power 60 W
11.5.2 Output Data
Table 100 Output data
Voltage per output (1 - 6)
+15 V DC
1)
Current per output (1 - 6)
Max. 500 mA
1)
Tolerance ±1.0 V at TMA current 0 - 300 mA.
Tolerance ±1.5 V at TMA current 300 - 500 mA.
EN/LZT 720 0008 P2A
2001-11-28
169 (485)
© Ericsson Radio Systems AB
— All Rights Reserved —
Preliminary