Radio Congurations, RBS 2206
SCC 1 x 4 can be achieved as a subset of either SCC 3 x 4 or 2 x 6.
SCC 1 x 6 can be achieved as a subset of SCC 2 x 6.
SCC 2 x 4 can be achieved as a subset of SCC 3 x 4 or 2 x 6.
SCC 3 x 2 can be achieved with use of SCC 3 x 4.
SCC 1 x 2 and 1 x 4 require one CDU-G.
SCC 2 x 2 and 1 x 6 require two CDU-Gs.
SCC 3 x 2 requires three CDU-Gs.
Table 26 CDU-G congurations with hybrid combiner in a partly-equipped cabinet only
SCC Conguration TMA Number of
Antennas
Allowed Number of dTRUs
1x4 G9deh_2.4 No (2) (0) (0) (0..2) (0) (0)
G9deht_2.4 M (2) (0) (0) (0..2) (0) (0)
G18dh_2.4 No (2) (0) (0) (0..2) (0) (0)
G18dht_2.4 M (2) (0) (0) (0..2) (0) (0)
G19dh_2.4 No (2) (0) (0) (0..2) (0) (0)
G19dht_2.4 M (2) (0) (0) (0..2) (0) (0)
2x4 2 x G9deh_2.4 No (2) (2) (0) (0..2) (0..2) (0)
2 x G9deht_2.4 M (2) (2) (0) (0..2) (0..2) (0)
2 x G18dh_2.4 No (2) (2) (0) (0..2) (0..2) (0)
2 x G18dht_2.4 M (2) (2) (0) (0..2) (0..2) (0)
2 x G19dh_2.4 No (2) (2) (0) (0..2) (0..2) (0)
2 x G19dht_2.4 M (2) (2) (0) (0..2) (0..2) (0)
1x8 G9deh_4.8 No (4) (0) (0..4) (0)
G9deht_4.8 M (4) (0) (0..4) (0)
G18dh_4.8 No (4) (0) (0..4) (0)
G18dht_4.8 M (4) (0) (0..4) (0)
G19dh_4.8 No (4) (0) (0..4) (0)
G19dht_4.8 M (4) (0) (0..4) (0)
M = Mandatory
4.7.2 GSM 900/GSM 1800 Dual Band Congurations
The notation for dual band congurations is done with the lower
frequency (900 MHz) conguration to the left and the higher frequency
(1800 MHz) conguration to the right, separated by the | symbol. This
notation is valid regardless of the position in the cabinet.
EN/LZT 720 0008 R1A
2001-06-26
71 (421)
© Ericsson Radio Systems AB