Reference Manual
Table Of Contents
- RBS 2206 Reference Manual
- Contents
- Preface
- Product Safety Requirements RBS 2000
- Environmental Capabilities
- Scope
- Terminology
- References
- Transport -40 C - +70 C
- Storage -25 C - +55 C
- Handling -40 C - +70 C
- Operation Indoor +5 C - +40 C
- Operation Outdoor -33 C - +40 C
- Operation Outdoor -33 C - +45 C
- Operation Outdoor -33 C - +55 C
- Operation Mast Mounted Equipment -33 C - +45 C
- Operation Mast Mounted Equipment -33 C - +55 C
- Radio Configurations, RBS 2206
- Product Data
- Unit Description, DXU-21
- Unit Description, dTRU
- Unit Decription, CDU-G and CDU-F
- Unit Description, CXU-10
- Unit Description, FCU-01
- Unit Description, DC-Filter 01
- Unit Description, PSU 1200 W
- Unit Description, ACCU/DCCU
- Unit Description, IDM
- Broadcast
- Common Control Channel Handling
- Physical Channel Handling
- Speech and Data Services
- Packet Data Services
- Call Control
- References
- Channel Activation
- Adaptive Frame Alignment
- Asynchronous Handover Detection
- RF Channel Release
- Deactivate SACCH
- Link Establish Indication
- Link Release Indication
- Link Establishment Request
- Link Release Request
- Transparent Message Transmission
- Transparent Message Reception
- SACCH Info Modify
- LAPDm
- Channel Reactivation
- Power Information
- GPRS, Physical Link Layer
- Base Station Power Control
- Channel Measurements
- Discontinuous Transmission
- Frequency Hopping
- Encryption
- Mode Modify
- Mobile Station Power Control
- Short Message Service
- Diversity Supervision
- Synchronization
- Radio Reception
- Radio Transmission
- Frequency Allocation Support
- Restart and Recovery
- Function Change
- Functionality Administration
- Operation and Maintenance Support
- References
- Concepts
- Buttons
- Change RU to Local Mode
- Change RU to Remote Mode
- Change RU to Remote Mode Cancel
- Change SW Power Boost Slave RU to Local Mode
- Loop Control
- RF Loop Test Supervision
- Calendar Time Request
- RSSI Temperature Compensation
- Max Cooling
- Fault Indicator
- BS Fault Indicator
- Operational Indicator
- Tx Not Enabled Indicator
- Local Mode Indicator
- External Alarms Indicator
- DC Disconnected Indicator
- Battery Mode Indicator
- Bat Disconnected Indicator
- AC Fault Indicator
- Test Result Indicators (not used)
- Local Mode in Progress
- Installation Data Handling
- Self Test and Supervision
- Diagnostics and Fault Handling
- Operation and Maintenance Terminal
- External Alarms
- Handling of Auxiliary Equipment
- Climate Protection
- EMC Capabilities
- Transmission Interface Handling G.703 2048 kbit/s
- Transmission Interface Handling DS1 1544 kbit/s
- Terrestrial Link Handling
- Channel Distribution Function
- Transport network O&M functions-DXX Support
- BTS Parameter Limitations
- Glossary
BTS Parameter Limitations
52.3.13 IS Connection List
BTS-supported value range:
ICP: 4 – 127
(dec)
132 – 351
(dec)
512 – 583
(dec)
640 – 711
(dec)
CI: 1 – 72
(dec)
The IWD-defined value ranges:
ICP: 0 – 1023
(dec)
CI: 1 – 255
(dec)
Note: There are limitations for specific combinations. For more
information see the figure in Appendix.
52.3.14 Local Access State
BTS-supported value range:
Local Access State parameter: 0
IWD-defined value range: 0 – 1
52.3.15 MO Identifier
Table 152 BTS-supported/IWD-defined value range
MO class BTS-supported value (hex) IWD-defined value (hex)
Instance number Instance number
TRXC
01 00 – 0B 01 00 – 0F
TX 0B 00 – 0B 0B 00 – 0F
RX 0C 00 – 0B 0C 00 – 0F
52.3.16 MO State
Table 153 BTS-supported codes
Code MO State Parameter Used by MO
00 Reset CF, IS, TRXC, RX, TF, TS, TX, DP, CON
01 Started CF, TRXC
02 Enabled IS, RX, TF, TS, TX, DP, CON
03 Disabled IS, RX, TF, TS, TX, DP, CON
IWD-defined value range: 00 – 03
52.3.17 Power
Note: Only the following macro configurations are supported:
RBS 2101, RBS 2102 and RBS 2202 with configurations
1x2, 2x2, 3x2, CDU-A for 900 MHz, CDU-A with TMA for
1800 MHz and 1900 MHz.
EN/LZT 720 0008 R1A
2001-06-26
403 (421)
© Ericsson Radio Systems AB
— All Rights Reserved —