Reference Manual

Table Of Contents
BTS Parameter Limitations
52 BTS Parameter Limitations
This document species congurable BTS parameters with limitations
compared with the parameter ranges in the Abis O&M IWD. BTS
parameters with no limitations compared to the Abis O&M IWD are not
stated in this document.
52.1 Purpose and Readers
The purpose is to show BTS parameters with parameter range
limitations compared to the Abis O&M IWD.
People involved in the preparation of data transcripts for the BSC are
the target group of this specication.
52.2 References
6/155 19HSC 103 12 Uen
Abis O&M Interface, Part II, Procedures
5/155 19HSC 103 12 Uen
Abis O&M Interface, Part I, Model
3/1551APT 210 09 Uen
Translation of Abis O&M IWD Parameters - BSC Command
Parameters
52.3 Parameters
The parameters listed in this document are extracted from the Data
Elements listed in the Abis O&M IWD document (see reference 1).
This document states the BTS parameters with parameter range
limitations compared with the Abis O&M IWD.
For each parameter in the list, the range supported by the BTS and the
Abis O&M IWD is stated.
All coding in the document is in hexadecimal (hex) representation if
nothing else is stated.
Note: See reference 3 for BSC Commands.
52.3.1 Accordance Indication
BTS-supported value range:
AIP: 0 1, 3
IWD-dened value range: 0 3
52.3.2 Alarm Status Type
BTS-supported value range:
Alarm status type: 1
IWD
EN/LZT 720 0008 R1A
2001-06-26
399 (421)
© Ericsson Radio Systems AB
All Rights Reserved