Reference Manual
Table Of Contents
- RBS 2206 Reference Manual
- Contents
- Preface
- Product Safety Requirements RBS 2000
- Environmental Capabilities
- Scope
- Terminology
- References
- Transport -40 C - +70 C
- Storage -25 C - +55 C
- Handling -40 C - +70 C
- Operation Indoor +5 C - +40 C
- Operation Outdoor -33 C - +40 C
- Operation Outdoor -33 C - +45 C
- Operation Outdoor -33 C - +55 C
- Operation Mast Mounted Equipment -33 C - +45 C
- Operation Mast Mounted Equipment -33 C - +55 C
- Radio Configurations, RBS 2206
- Product Data
- Unit Description, DXU-21
- Unit Description, dTRU
- Unit Decription, CDU-G and CDU-F
- Unit Description, CXU-10
- Unit Description, FCU-01
- Unit Description, DC-Filter 01
- Unit Description, PSU 1200 W
- Unit Description, ACCU/DCCU
- Unit Description, IDM
- Broadcast
- Common Control Channel Handling
- Physical Channel Handling
- Speech and Data Services
- Packet Data Services
- Call Control
- References
- Channel Activation
- Adaptive Frame Alignment
- Asynchronous Handover Detection
- RF Channel Release
- Deactivate SACCH
- Link Establish Indication
- Link Release Indication
- Link Establishment Request
- Link Release Request
- Transparent Message Transmission
- Transparent Message Reception
- SACCH Info Modify
- LAPDm
- Channel Reactivation
- Power Information
- GPRS, Physical Link Layer
- Base Station Power Control
- Channel Measurements
- Discontinuous Transmission
- Frequency Hopping
- Encryption
- Mode Modify
- Mobile Station Power Control
- Short Message Service
- Diversity Supervision
- Synchronization
- Radio Reception
- Radio Transmission
- Frequency Allocation Support
- Restart and Recovery
- Function Change
- Functionality Administration
- Operation and Maintenance Support
- References
- Concepts
- Buttons
- Change RU to Local Mode
- Change RU to Remote Mode
- Change RU to Remote Mode Cancel
- Change SW Power Boost Slave RU to Local Mode
- Loop Control
- RF Loop Test Supervision
- Calendar Time Request
- RSSI Temperature Compensation
- Max Cooling
- Fault Indicator
- BS Fault Indicator
- Operational Indicator
- Tx Not Enabled Indicator
- Local Mode Indicator
- External Alarms Indicator
- DC Disconnected Indicator
- Battery Mode Indicator
- Bat Disconnected Indicator
- AC Fault Indicator
- Test Result Indicators (not used)
- Local Mode in Progress
- Installation Data Handling
- Self Test and Supervision
- Diagnostics and Fault Handling
- Operation and Maintenance Terminal
- External Alarms
- Handling of Auxiliary Equipment
- Climate Protection
- EMC Capabilities
- Transmission Interface Handling G.703 2048 kbit/s
- Transmission Interface Handling DS1 1544 kbit/s
- Terrestrial Link Handling
- Channel Distribution Function
- Transport network O&M functions-DXX Support
- BTS Parameter Limitations
- Glossary
Channel Distribution Function
50.3.2 Scanning of Terrestrial Channels
The function is initiated:
•
When the CMRU is in Local mode and the Remote button is
pressed
• When the CMRU is in Remote mode and (re-)started
• When CF has lost its layer 2 connection to BSC
• When the CF link is disconnected (reception of DISC command
frame)
RBS searches all terrestrial signalling channels, plus a number of
unoccupied terrestrial channels, for data link establishment attempts
directed towards CF.
Searching for the establishment attempt is performed by the CF in
intervals of one second. The searching can be performed in two ways.
Initially, when no valid CDF configuration exists, one set of unoccupied
terrestrial channels is searched in each interval. If no establishment
attempt is found during an interval, the search is continued on the next
set of unoccupied terrestrial channels. The search is repeated until an
establishment attempt is found.
If the scanning function is initiated when a valid CDF configuration
exists, the search in each interval is performed on all the configured
terrestrial signalling channels plus one set of unoccupied terrestrial
channels. Thus all unoccupied terrestrial channels are searched in a
cyclic way and all configured terrestrial signalling channels are searched
continuously.
After a search-time of 5 minutes, the entire configuration of the channel
distribution function except TN O&M channel is erased (all set up
connections are lost and have to be reconfigured). The search continues
but now all terrestrial channels are defined as unoccupied.
Timeslot for TN O&M is considered as occupied and is not scanned in
CF scanning procedure.
The function is terminated when the layer 2 link to CF is established or
when CMRU enters Local mode.
50.3.3 Sharing Terrestrial Signalling Channel
The function is initiated when the channel distribution function becomes
configured in such a way that the same terrestrial signalling channel is
used for signalling to both MO CF and to one or more TRXs. This is
the normal condition that occurs at configuration of the first TRX.
It is also initiated when RBS has, during scanning of terrestrial
channels, found a link establishment to CF on a terrestrial signalling
channel already used for signalling to one or more TRXs.
The function shares signalling to/from MO CF and signalling to/from
one or more TRXs on a shared terrestrial signalling channel.
EN/LZT 720 0008 R1A
2001-06-26
379 (421)
© Ericsson Radio Systems AB
— All Rights Reserved —