Reference Manual
Table Of Contents
- RBS 2206 Reference Manual
- Contents
- Preface
- Product Safety Requirements RBS 2000
- Environmental Capabilities
- Scope
- Terminology
- References
- Transport -40 C - +70 C
- Storage -25 C - +55 C
- Handling -40 C - +70 C
- Operation Indoor +5 C - +40 C
- Operation Outdoor -33 C - +40 C
- Operation Outdoor -33 C - +45 C
- Operation Outdoor -33 C - +55 C
- Operation Mast Mounted Equipment -33 C - +45 C
- Operation Mast Mounted Equipment -33 C - +55 C
- Radio Configurations, RBS 2206
- Product Data
- Unit Description, DXU-21
- Unit Description, dTRU
- Unit Decription, CDU-G and CDU-F
- Unit Description, CXU-10
- Unit Description, FCU-01
- Unit Description, DC-Filter 01
- Unit Description, PSU 1200 W
- Unit Description, ACCU/DCCU
- Unit Description, IDM
- Broadcast
- Common Control Channel Handling
- Physical Channel Handling
- Speech and Data Services
- Packet Data Services
- Call Control
- References
- Channel Activation
- Adaptive Frame Alignment
- Asynchronous Handover Detection
- RF Channel Release
- Deactivate SACCH
- Link Establish Indication
- Link Release Indication
- Link Establishment Request
- Link Release Request
- Transparent Message Transmission
- Transparent Message Reception
- SACCH Info Modify
- LAPDm
- Channel Reactivation
- Power Information
- GPRS, Physical Link Layer
- Base Station Power Control
- Channel Measurements
- Discontinuous Transmission
- Frequency Hopping
- Encryption
- Mode Modify
- Mobile Station Power Control
- Short Message Service
- Diversity Supervision
- Synchronization
- Radio Reception
- Radio Transmission
- Frequency Allocation Support
- Restart and Recovery
- Function Change
- Functionality Administration
- Operation and Maintenance Support
- References
- Concepts
- Buttons
- Change RU to Local Mode
- Change RU to Remote Mode
- Change RU to Remote Mode Cancel
- Change SW Power Boost Slave RU to Local Mode
- Loop Control
- RF Loop Test Supervision
- Calendar Time Request
- RSSI Temperature Compensation
- Max Cooling
- Fault Indicator
- BS Fault Indicator
- Operational Indicator
- Tx Not Enabled Indicator
- Local Mode Indicator
- External Alarms Indicator
- DC Disconnected Indicator
- Battery Mode Indicator
- Bat Disconnected Indicator
- AC Fault Indicator
- Test Result Indicators (not used)
- Local Mode in Progress
- Installation Data Handling
- Self Test and Supervision
- Diagnostics and Fault Handling
- Operation and Maintenance Terminal
- External Alarms
- Handling of Auxiliary Equipment
- Climate Protection
- EMC Capabilities
- Transmission Interface Handling G.703 2048 kbit/s
- Transmission Interface Handling DS1 1544 kbit/s
- Terrestrial Link Handling
- Channel Distribution Function
- Transport network O&M functions-DXX Support
- BTS Parameter Limitations
- Glossary
Transmission Interface Handling DS1 1544 kbit/s
48.3.5 Administration
Supervision of transmission faults and transmission quality can be
performed in different ways. With the help of parameters, the
supervision can be configured to meet a wide range of requirements.
The configuration parameters can only be changed when the AO DP is
in state “Disable”. The parameters of interest are given below.
•
The parameters P and Q
−
The parameters P and Q are used for defining unavailable
state
−
Value range is 5-15 s
−
Default value is 10 s
•
The parameter N1
−
The parameter N1 defines the threshold numbers for SES.
Value range is 1-1000
− Default value is 320
•
The configuration parameter T
− The parameter T defines the time interval for ERATE
supervision
−
Value range is 1-5 s
− Default value is 2 s
• The configuration parameter AFT
−
The configuration parameter AFT defines the Alarm
Filtering Time for all the fault supervision functions
except RAI supervision
− Value range is 50-5000 ms
− Default value is 125 ms
− The resolution is 1 ms, but the accuracy is ±25 ms
• The configuration parameter AFT RAI
− The configuration parameter AFT RAI defines the Alarm
Filtering Time for the fault supervision function RAI
supervision
− Value range is 50-5000 ms
− Default value is 125 ms
− The resolution is 1 ms, but the accuracy is ±25 ms
• Base interval for ES, SES, UAS, BFF and SF
− Valid values: 60 and 126 seconds. The value 126
seconds must be used when BFF supervision is activated
in the BSC.
370 (421)
EN/LZT 720 0008 R1A
2001-06-26
© Ericsson Radio Systems AB
— All Rights Reserved —