Reference Manual
Table Of Contents
- RBS 2206 Reference Manual
- Contents
- Preface
- Product Safety Requirements RBS 2000
- Environmental Capabilities
- Scope
- Terminology
- References
- Transport -40 C - +70 C
- Storage -25 C - +55 C
- Handling -40 C - +70 C
- Operation Indoor +5 C - +40 C
- Operation Outdoor -33 C - +40 C
- Operation Outdoor -33 C - +45 C
- Operation Outdoor -33 C - +55 C
- Operation Mast Mounted Equipment -33 C - +45 C
- Operation Mast Mounted Equipment -33 C - +55 C
- Radio Configurations, RBS 2206
- Product Data
- Unit Description, DXU-21
- Unit Description, dTRU
- Unit Decription, CDU-G and CDU-F
- Unit Description, CXU-10
- Unit Description, FCU-01
- Unit Description, DC-Filter 01
- Unit Description, PSU 1200 W
- Unit Description, ACCU/DCCU
- Unit Description, IDM
- Broadcast
- Common Control Channel Handling
- Physical Channel Handling
- Speech and Data Services
- Packet Data Services
- Call Control
- References
- Channel Activation
- Adaptive Frame Alignment
- Asynchronous Handover Detection
- RF Channel Release
- Deactivate SACCH
- Link Establish Indication
- Link Release Indication
- Link Establishment Request
- Link Release Request
- Transparent Message Transmission
- Transparent Message Reception
- SACCH Info Modify
- LAPDm
- Channel Reactivation
- Power Information
- GPRS, Physical Link Layer
- Base Station Power Control
- Channel Measurements
- Discontinuous Transmission
- Frequency Hopping
- Encryption
- Mode Modify
- Mobile Station Power Control
- Short Message Service
- Diversity Supervision
- Synchronization
- Radio Reception
- Radio Transmission
- Frequency Allocation Support
- Restart and Recovery
- Function Change
- Functionality Administration
- Operation and Maintenance Support
- References
- Concepts
- Buttons
- Change RU to Local Mode
- Change RU to Remote Mode
- Change RU to Remote Mode Cancel
- Change SW Power Boost Slave RU to Local Mode
- Loop Control
- RF Loop Test Supervision
- Calendar Time Request
- RSSI Temperature Compensation
- Max Cooling
- Fault Indicator
- BS Fault Indicator
- Operational Indicator
- Tx Not Enabled Indicator
- Local Mode Indicator
- External Alarms Indicator
- DC Disconnected Indicator
- Battery Mode Indicator
- Bat Disconnected Indicator
- AC Fault Indicator
- Test Result Indicators (not used)
- Local Mode in Progress
- Installation Data Handling
- Self Test and Supervision
- Diagnostics and Fault Handling
- Operation and Maintenance Terminal
- External Alarms
- Handling of Auxiliary Equipment
- Climate Protection
- EMC Capabilities
- Transmission Interface Handling G.703 2048 kbit/s
- Transmission Interface Handling DS1 1544 kbit/s
- Terrestrial Link Handling
- Channel Distribution Function
- Transport network O&M functions-DXX Support
- BTS Parameter Limitations
- Glossary
Transmission Interface Handling DS1 1544 kbit/s
• RAI
ES are not counted during unavailable state.
Both ES counters are reported after each BI.
Severely Errored Seconds supervision
An SES is a is a second with at least one of the events:
• N1 CRC-6 errors
• LOF alignment
• LOS
• AIS
• RAI
Two counters for severely errored seconds exist. Both are derived from
the downstream PCM port, but one is closely connected to downstream
faults while the other one is related to upstream faults.
The downstream counter is incremented by 1 for each second with at
least one of the events:
•
N1 CRC-6 errors or
•
1 LOF or
•
1 LOS or
•
1 AIS
The upstream counter is incremented by 1 for each second with at least
one
• RAI
SES are not counted during unavailable state.
Both SES contours are reported after each BI.
UAS and Unavailable State supervision
UAS is a count of one-second intervals during which service is
unavailable. This period of time is referred to as the unavailable state.
The two directions (upstream and downstream) are supervised
separately. That is, one of the directions can be in the unavailable state
but the other is in the available state.
The counting of ES and SES is stopped for both directions as soon as at
least one of the directions is in the unavailable state.
An unavailable state for one direction is declared at the onset of P
consecutive SES for the direction of interest. These P seconds are
considered to be part of the unavailable time. A new period of available
state begins at the onset of Q consecutive seconds with no SES detected.
These Q seconds are considered to be part of the available time.
The number of unavailable seconds for each direction is reported after
each BI.
EN/LZT 720 0008 R1A
2001-06-26
369 (421)
© Ericsson Radio Systems AB
— All Rights Reserved —