Reference Manual
Table Of Contents
- RBS 2206 Reference Manual
- Contents
- Preface
- Product Safety Requirements RBS 2000
- Environmental Capabilities
- Scope
- Terminology
- References
- Transport -40 C - +70 C
- Storage -25 C - +55 C
- Handling -40 C - +70 C
- Operation Indoor +5 C - +40 C
- Operation Outdoor -33 C - +40 C
- Operation Outdoor -33 C - +45 C
- Operation Outdoor -33 C - +55 C
- Operation Mast Mounted Equipment -33 C - +45 C
- Operation Mast Mounted Equipment -33 C - +55 C
- Radio Configurations, RBS 2206
- Product Data
- Unit Description, DXU-21
- Unit Description, dTRU
- Unit Decription, CDU-G and CDU-F
- Unit Description, CXU-10
- Unit Description, FCU-01
- Unit Description, DC-Filter 01
- Unit Description, PSU 1200 W
- Unit Description, ACCU/DCCU
- Unit Description, IDM
- Broadcast
- Common Control Channel Handling
- Physical Channel Handling
- Speech and Data Services
- Packet Data Services
- Call Control
- References
- Channel Activation
- Adaptive Frame Alignment
- Asynchronous Handover Detection
- RF Channel Release
- Deactivate SACCH
- Link Establish Indication
- Link Release Indication
- Link Establishment Request
- Link Release Request
- Transparent Message Transmission
- Transparent Message Reception
- SACCH Info Modify
- LAPDm
- Channel Reactivation
- Power Information
- GPRS, Physical Link Layer
- Base Station Power Control
- Channel Measurements
- Discontinuous Transmission
- Frequency Hopping
- Encryption
- Mode Modify
- Mobile Station Power Control
- Short Message Service
- Diversity Supervision
- Synchronization
- Radio Reception
- Radio Transmission
- Frequency Allocation Support
- Restart and Recovery
- Function Change
- Functionality Administration
- Operation and Maintenance Support
- References
- Concepts
- Buttons
- Change RU to Local Mode
- Change RU to Remote Mode
- Change RU to Remote Mode Cancel
- Change SW Power Boost Slave RU to Local Mode
- Loop Control
- RF Loop Test Supervision
- Calendar Time Request
- RSSI Temperature Compensation
- Max Cooling
- Fault Indicator
- BS Fault Indicator
- Operational Indicator
- Tx Not Enabled Indicator
- Local Mode Indicator
- External Alarms Indicator
- DC Disconnected Indicator
- Battery Mode Indicator
- Bat Disconnected Indicator
- AC Fault Indicator
- Test Result Indicators (not used)
- Local Mode in Progress
- Installation Data Handling
- Self Test and Supervision
- Diagnostics and Fault Handling
- Operation and Maintenance Terminal
- External Alarms
- Handling of Auxiliary Equipment
- Climate Protection
- EMC Capabilities
- Transmission Interface Handling G.703 2048 kbit/s
- Transmission Interface Handling DS1 1544 kbit/s
- Terrestrial Link Handling
- Channel Distribution Function
- Transport network O&M functions-DXX Support
- BTS Parameter Limitations
- Glossary
Transmission Interface Handling DS1 1544 kbit/s
Downstream The path for information from the BSC to
the MS, see Figure 105 on page 363.
Upstream The path for information from the MS to
the BSC, see Figure 105 on page 363.
Linear Cascade Chain A cascade of RBS:s according to Figure
105 on page 363.
01_0306A
RBS 2
PCM-A
PCM-B
PCM-A
PCM-B
Downstream Downstream
Mobile
Station
Downstream
Upstream
Upstream
RBS 1
BSC
Upstream
Upstream
Figure 105 Upstream and Downstream
48.3 Functions
48.3.1 Layer 1 Termination DS1 1544 kbit/s
The function is initiated during restart of DXU.
Layer 1 termination on the transport network interface includes:
• Physical and electrical characteristics according to ANSI T1.403
(interface at 1544 kbit/s, one pair for each direction of
transmission, test load impedance 100 ohm, resistive).
•
Frame structure according to ANSI T1.403, ESF. T option only,
see Table 149 on page 362. 8 traffic bits in all frames in the ESF.
• Line coding B8ZS according to AT&T section 4.2.2. (ref. 4).
B8ZS is the only technology to provide 64 kb/s Clear Channel
Capability (64 CCC).
• When no message is sent on the Data Link (DL, message bit m)
in the ESF, an idle pattern (01111110) (ref. ANSI 6.4(2)) is
transmitted. The Data Link is used for RAI (Remote Alarm
Indication, "Yellow Alarm") information in both directions. See
Table 149 on page 362.
• Frame alignment and CRC-6 procedures according to ANSI
T1.403, 24-frame ESF.
EN/LZT 720 0008 R1A
2001-06-26
363 (421)
© Ericsson Radio Systems AB
— All Rights Reserved —