Reference Manual

Table Of Contents
EMC Capabilities
Table 140 Surge test 1.2/50 pulses
Limit standard
EN 61000-4-5
Test level 2 kV common mode between line and cabinet ground reference
1 kV differential mode between line and line
Performance Criteria B for a complete system
Criteria TT for transmitter units
Criteria TR for receiver units
Table 141 Surge test 10/700 pulses
Limit standard EN 61000-4-5
Test level 1 kV common mode between line and cabinet ground reference
1 kV differential mode between line and line
Performance Criteria B for a complete system
Criteria TT for transmitter units
Criteria TR for receiver units
Table 142 Power induction test
Basic standard ITU-T K.20
Test level 600 V(rms) common mode
Performance Criteria A(K.20)
Table 143 RF common mode test
Limit standard ETS 300 342-2
Test level 10 V(rms)
Performance Criteria A for a complete system
Criteria CT for transmitter units
Criteria CR for receiver units
46.3.7 Radiated Immunity of Enclosure Port
Table 144 Immunity of continuous electric elds
Basic standard IEC 801-3
Test level 10 V/m
Performance Criteria A
Limit standard ETS 300 342-2
Test level 10 V/m, 80 MHz - 1 GHz
Frequency range 30 V/m, 1 GHz-20 GHz
Performance Criteria A for a complete system
EN/LZT 720 0008 R1A
2001-06-26
347 (421)
© Ericsson Radio Systems AB
All Rights Reserved