Reference Manual

Table Of Contents
EMC Capabilities
Performance Criteria TT Transient phenomena applied to
Transmitters. A communication link shall
be established at the start of the test and
maintained during and after injection of
the transients
Performance Criteria CR Continous phenomena applied to
Receivers. A communication link shall be
established at the start of the test and
maintained during the test. For the system
the RXQUAL (as dened in GSM 05.08)
of the uplink shall not exceed three,
measured during each individual exposure
in the test sequence
Performance Criteria TR Transient phenomena applied to Receivers.
A communication link shall be established
at the start of the test and maintained
during and after injection of the transients
Performance Criteria A(K.20): The test object shall withstand the test
without damage or other disturbances after
the test
Performance Criteria B(K.20): A re hazard should not arise in the test
object. Any damage or permanent
malfunction occuring should be conned
to a small number of external line
interface circuits.
46.3 Capabilities
46.3.1 RBS Description
Hardware
The capabilities are tested for an RBS equipped with a minimum
representative conguration of units. This system is representative of
installed systems in terms of function, which includes at least one of
each function unit type, and electromagnetic radiation characteristics.
The number and types of sub-units are given from results of
investigations in accordance with ETS 300 342-2, Nov 1994.
Software
The capabilities are valid for a standard setup of system software with
default parameters.
Performance
For the immunity capabilities the RBS is operating and will full the
performance criteria stated for each test.
For emission capabilities all equipment in the RBS was enabled during
verication to create the worst emission case.
EN/LZT 720 0008 R1A
2001-06-26
343 (421)
© Ericsson Radio Systems AB
All Rights Reserved