- Product Safety Requirements RBS 2000
- Environmental Capabilities
- Scope
- Terminology
- References
- Transport -40 C - +70 C
- Storage -25 C - +55 C
- Handling -40 C - +70 C
- Operation Indoor +5 C - +40 C
- Operation Outdoor -33 C - +40 C
- Operation Outdoor -33 C - +45 C
- Operation Outdoor -33 C - +55 C
- Operation Mast Mounted Equipment -33 C - +45 C
- Operation Mast Mounted Equipment -33 C - +55 C
- Radio Configurations, RBS 2206
- Product Data
- Unit Description, DXU-21
- Unit Description, dTRU
- Unit Decription, CDU-G and CDU-F
- Unit Description, CXU-10
- Unit Description, FCU-01
- Unit Description, DC-Filter 01
- Unit Description, PSU 1200 W
- Unit Description, ACCU/DCCU
- Unit Description, IDM
- Broadcast
- Common Control Channel Handling
- Physical Channel Handling
- Speech and Data Services
- Packet Data Services
- Call Control
- References
- Channel Activation
- Adaptive Frame Alignment
- Asynchronous Handover Detection
- RF Channel Release
- Deactivate SACCH
- Link Establish Indication
- Link Release Indication
- Link Establishment Request
- Link Release Request
- Transparent Message Transmission
- Transparent Message Reception
- SACCH Info Modify
- LAPDm
- Channel Reactivation
- Power Information
- GPRS, Physical Link Layer
- Base Station Power Control
- Channel Measurements
- Discontinuous Transmission
- Frequency Hopping
- Encryption
- Mode Modify
- Mobile Station Power Control
- Short Message Service
- Diversity Supervision
- Synchronization
- Radio Reception
- Radio Transmission
- Frequency Allocation Support
- Restart and Recovery
- Function Change
- Functionality Administration
- Operation and Maintenance Support
- References
- Concepts
- Buttons
- Change RU to Local Mode
- Change RU to Remote Mode
- Change RU to Remote Mode Cancel
- Change SW Power Boost Slave RU to Local Mode
- Loop Control
- RF Loop Test Supervision
- Calendar Time Request
- RSSI Temperature Compensation
- Max Cooling
- Fault Indicator
- BS Fault Indicator
- Operational Indicator
- Tx Not Enabled Indicator
- Local Mode Indicator
- External Alarms Indicator
- DC Disconnected Indicator
- Battery Mode Indicator
- Bat Disconnected Indicator
- AC Fault Indicator
- Test Result Indicators (not used)
- Local Mode in Progress
- Installation Data Handling
- Self Test and Supervision
- Diagnostics and Fault Handling
- Operation and Maintenance Terminal
- External Alarms
- Handling of Auxiliary Equipment
- Climate Protection
- EMC Capabilities
- Transmission Interface Handling G.703 2048 kbit/s
- Transmission Interface Handling DS1 1544 kbit/s
- Terrestrial Link Handling
- Channel Distribution Function
- Transport network O&M functions-DXX Support
- BTS Parameter Limitations
- Glossary
EMC Capabilities
46 EMC Capabilities
This specification covers the capabilities of the RBS 2000 in respect of
EMC (ElectroMagnetic Compatibility). The capabilities include
conducted and radiated emission as well as conducted and radiated
immunity thresholds.
The internal EMC capabilities of RBS 2000 and interference appearing
on antenna ports are not covered by this chapter.
46.1 References
1. 89/336/EEC EMC directive
Council directive of 3 May 1989 on approximation of laws of the
Member States relating to electromagnetic compatibility
2. ETS 300 342–2, Nov 1994
EMC for European digital cellular telecommunication (GSM)
mobile radio and ancillary equipment.
3. EN 55 022, April 1987
Limits and methods of Measurement of Radio Interference
Characteristics of Information Technology Equipment
4. EN 50 081-1, January 1992
Electromagnetic compatibility - Generic emission standard, Part 1:
Residential, commercial and light industry
5. EN 50 082-1, January 1992
Electromagnetic compatibility - Generic immunity standard, Part
1: Residential, commercial and light industry
6. IEC 801-3, 1984
Radiated electromagnetic field requirement
7. EN 61000–3–2, EMC part 3, section 2
limits for harmonic current emissions, 1995
8. EN 61000–3–3, EMC part 3, section 2
limitation of voltage fluctuations and flicker in low-voltage supply
systems for equipment with rated current <16 A, 1994
9. EN 61000–4–2, 1995
Electrostatic discharge requirements
10. EN 61000–4–4, 1995
Electrical fast transient/burst requirement
11. EN 61000–4–5
Surge Immunity Requirements
12. EN 61000–4–8, 1993
EN/LZT 720 0008 R1A