Reference Manual
Table Of Contents
- RBS 2206 Reference Manual
- Contents
- Preface
- Product Safety Requirements RBS 2000
- Environmental Capabilities
- Scope
- Terminology
- References
- Transport -40 C - +70 C
- Storage -25 C - +55 C
- Handling -40 C - +70 C
- Operation Indoor +5 C - +40 C
- Operation Outdoor -33 C - +40 C
- Operation Outdoor -33 C - +45 C
- Operation Outdoor -33 C - +55 C
- Operation Mast Mounted Equipment -33 C - +45 C
- Operation Mast Mounted Equipment -33 C - +55 C
- Radio Configurations, RBS 2206
- Product Data
- Unit Description, DXU-21
- Unit Description, dTRU
- Unit Decription, CDU-G and CDU-F
- Unit Description, CXU-10
- Unit Description, FCU-01
- Unit Description, DC-Filter 01
- Unit Description, PSU 1200 W
- Unit Description, ACCU/DCCU
- Unit Description, IDM
- Broadcast
- Common Control Channel Handling
- Physical Channel Handling
- Speech and Data Services
- Packet Data Services
- Call Control
- References
- Channel Activation
- Adaptive Frame Alignment
- Asynchronous Handover Detection
- RF Channel Release
- Deactivate SACCH
- Link Establish Indication
- Link Release Indication
- Link Establishment Request
- Link Release Request
- Transparent Message Transmission
- Transparent Message Reception
- SACCH Info Modify
- LAPDm
- Channel Reactivation
- Power Information
- GPRS, Physical Link Layer
- Base Station Power Control
- Channel Measurements
- Discontinuous Transmission
- Frequency Hopping
- Encryption
- Mode Modify
- Mobile Station Power Control
- Short Message Service
- Diversity Supervision
- Synchronization
- Radio Reception
- Radio Transmission
- Frequency Allocation Support
- Restart and Recovery
- Function Change
- Functionality Administration
- Operation and Maintenance Support
- References
- Concepts
- Buttons
- Change RU to Local Mode
- Change RU to Remote Mode
- Change RU to Remote Mode Cancel
- Change SW Power Boost Slave RU to Local Mode
- Loop Control
- RF Loop Test Supervision
- Calendar Time Request
- RSSI Temperature Compensation
- Max Cooling
- Fault Indicator
- BS Fault Indicator
- Operational Indicator
- Tx Not Enabled Indicator
- Local Mode Indicator
- External Alarms Indicator
- DC Disconnected Indicator
- Battery Mode Indicator
- Bat Disconnected Indicator
- AC Fault Indicator
- Test Result Indicators (not used)
- Local Mode in Progress
- Installation Data Handling
- Self Test and Supervision
- Diagnostics and Fault Handling
- Operation and Maintenance Terminal
- External Alarms
- Handling of Auxiliary Equipment
- Climate Protection
- EMC Capabilities
- Transmission Interface Handling G.703 2048 kbit/s
- Transmission Interface Handling DS1 1544 kbit/s
- Terrestrial Link Handling
- Channel Distribution Function
- Transport network O&M functions-DXX Support
- BTS Parameter Limitations
- Glossary
Self Test and Supervision
40.4.1 Supervision of Buses
Purpose
The purpose of this function is to check the integrity of the data on the
buses.
Preconditions and Initiation
The function is automatically initiated at the start of the functions
driving and receiving information on the buses.
Description
Receive and transmit bus supervision encompasses buses between three
or more RUs or major functional blocks. The address or data buses of
the processors are not supervised by this specific function. The
supervision of the buses is achieved by comparison of data sent to the
bus driving function with the information on the bus, and by control
information embedded in the data. The function looks for expected
traffic on the bus. Traffic must be generated in absence of normal
traffic. Disturbances are reported to fault handling for filtering and fault
detection.
40.4.2 Supervision of Cables
Purpose
To detect removal of a cable.
Preconditions and Initiation
Initiates automatically at start of application software.
Description
All cables between the RUs are supervised. Removal of a cable during
operation is always detected by one of the following conditions:
•
No current in the cable
•
Missing logical signal
• Missing traffic message
It is possible to disable and enable the fault reporting for the cables
listed below using the OMT.
• CDU TRU PFWD cables
• CDU TRU PREF cables
• FU CU PFWD cables
• FU CU PREF cables
When the OMT is disconnected, the fault reporting is always enabled.
EN/LZT 720 0008 R1A
2001-06-26
307 (421)
© Ericsson Radio Systems AB
— All Rights Reserved —