Reference Manual
Table Of Contents
- RBS 2206 Reference Manual
- Contents
- Preface
- Product Safety Requirements RBS 2000
- Environmental Capabilities
- Scope
- Terminology
- References
- Transport -40 C - +70 C
- Storage -25 C - +55 C
- Handling -40 C - +70 C
- Operation Indoor +5 C - +40 C
- Operation Outdoor -33 C - +40 C
- Operation Outdoor -33 C - +45 C
- Operation Outdoor -33 C - +55 C
- Operation Mast Mounted Equipment -33 C - +45 C
- Operation Mast Mounted Equipment -33 C - +55 C
- Radio Configurations, RBS 2206
- Product Data
- Unit Description, DXU-21
- Unit Description, dTRU
- Unit Decription, CDU-G and CDU-F
- Unit Description, CXU-10
- Unit Description, FCU-01
- Unit Description, DC-Filter 01
- Unit Description, PSU 1200 W
- Unit Description, ACCU/DCCU
- Unit Description, IDM
- Broadcast
- Common Control Channel Handling
- Physical Channel Handling
- Speech and Data Services
- Packet Data Services
- Call Control
- References
- Channel Activation
- Adaptive Frame Alignment
- Asynchronous Handover Detection
- RF Channel Release
- Deactivate SACCH
- Link Establish Indication
- Link Release Indication
- Link Establishment Request
- Link Release Request
- Transparent Message Transmission
- Transparent Message Reception
- SACCH Info Modify
- LAPDm
- Channel Reactivation
- Power Information
- GPRS, Physical Link Layer
- Base Station Power Control
- Channel Measurements
- Discontinuous Transmission
- Frequency Hopping
- Encryption
- Mode Modify
- Mobile Station Power Control
- Short Message Service
- Diversity Supervision
- Synchronization
- Radio Reception
- Radio Transmission
- Frequency Allocation Support
- Restart and Recovery
- Function Change
- Functionality Administration
- Operation and Maintenance Support
- References
- Concepts
- Buttons
- Change RU to Local Mode
- Change RU to Remote Mode
- Change RU to Remote Mode Cancel
- Change SW Power Boost Slave RU to Local Mode
- Loop Control
- RF Loop Test Supervision
- Calendar Time Request
- RSSI Temperature Compensation
- Max Cooling
- Fault Indicator
- BS Fault Indicator
- Operational Indicator
- Tx Not Enabled Indicator
- Local Mode Indicator
- External Alarms Indicator
- DC Disconnected Indicator
- Battery Mode Indicator
- Bat Disconnected Indicator
- AC Fault Indicator
- Test Result Indicators (not used)
- Local Mode in Progress
- Installation Data Handling
- Self Test and Supervision
- Diagnostics and Fault Handling
- Operation and Maintenance Terminal
- External Alarms
- Handling of Auxiliary Equipment
- Climate Protection
- EMC Capabilities
- Transmission Interface Handling G.703 2048 kbit/s
- Transmission Interface Handling DS1 1544 kbit/s
- Terrestrial Link Handling
- Channel Distribution Function
- Transport network O&M functions-DXX Support
- BTS Parameter Limitations
- Glossary
Environmental Capabilities
3.9 Operation Outdoor -33
C - +45
C
The severity of the requirements is in conformity with: IEC 721-3-4
classes 4K2/4Z5/4Z7/4B1/4C2(4C3)/4S2/4M5. and ETS 300 019-1-4
Class 4.1. "NON-WEATHERPROTECTED location", except for the
temperature range which is extended to +45
C.
This clause refers to the environment which an RBS for outdoor
non-weather protected location shall endure.
The figures below refers to the environment that is surrounding the
cabinet and the temperature is the shaded air temperature.
3.9.1 Climatic Conditions
The severity of these requirements is in conformity with: IEC 721-3-4
classes 4K2/4Z5/4Z7. and ETS 300 019-1-4 Class 4.1. In addition to
this Ericsson demands more rigorous values than stated by IEC and
ETSI above.
The RBS shall be designed for a power loss of max. 48 hours. This
applies both to installation and operation.
Table 8
Environmental Unit Value
Parameters Normal Condition Non Destr.
Temperature
C
-33 - +45 -40 - +70
Relative Humidity % 15 - 100 15 - 100
3.9.2 Biological Conditions
The severity of these requirements is in conformity with: IEC 721-3-4
class /4B1/. and ETS 300 019-1-4 Class 4.1.
3.9.3 Chemically Active Substances
The severity of these requirements is in conformity with: IEC 721-3-4
classes /4C2(4C1)/. and ETS 300 019-1-4 Class 4.1.
Note: The values are average yearly levels of airborne
contaminants that can be accepted. It is assumed that one of
the contaminants is dominant at each site, and that the other
is present in insignificant amounts.
3.9.4 Mechanically Active Substances
The severity of these requirements is in conformity with: IEC 721-3-4
class /4S2/. and ETS 300 019-1-4 Class 4.1.
3.9.5 Mechanical Conditions
The severity of these requirements are in conformity with: IEC 721-3-4
class /4M5/. and ETS 300 019-1-4 Class 4.1.
26 (421)
EN/LZT 720 0008 R1A
2001-06-26
© Ericsson Radio Systems AB
— All Rights Reserved —