Reference Manual
Table Of Contents
- RBS 2206 Reference Manual
- Contents
- Preface
- Product Safety Requirements RBS 2000
- Environmental Capabilities
- Scope
- Terminology
- References
- Transport -40 C - +70 C
- Storage -25 C - +55 C
- Handling -40 C - +70 C
- Operation Indoor +5 C - +40 C
- Operation Outdoor -33 C - +40 C
- Operation Outdoor -33 C - +45 C
- Operation Outdoor -33 C - +55 C
- Operation Mast Mounted Equipment -33 C - +45 C
- Operation Mast Mounted Equipment -33 C - +55 C
- Radio Configurations, RBS 2206
- Product Data
- Unit Description, DXU-21
- Unit Description, dTRU
- Unit Decription, CDU-G and CDU-F
- Unit Description, CXU-10
- Unit Description, FCU-01
- Unit Description, DC-Filter 01
- Unit Description, PSU 1200 W
- Unit Description, ACCU/DCCU
- Unit Description, IDM
- Broadcast
- Common Control Channel Handling
- Physical Channel Handling
- Speech and Data Services
- Packet Data Services
- Call Control
- References
- Channel Activation
- Adaptive Frame Alignment
- Asynchronous Handover Detection
- RF Channel Release
- Deactivate SACCH
- Link Establish Indication
- Link Release Indication
- Link Establishment Request
- Link Release Request
- Transparent Message Transmission
- Transparent Message Reception
- SACCH Info Modify
- LAPDm
- Channel Reactivation
- Power Information
- GPRS, Physical Link Layer
- Base Station Power Control
- Channel Measurements
- Discontinuous Transmission
- Frequency Hopping
- Encryption
- Mode Modify
- Mobile Station Power Control
- Short Message Service
- Diversity Supervision
- Synchronization
- Radio Reception
- Radio Transmission
- Frequency Allocation Support
- Restart and Recovery
- Function Change
- Functionality Administration
- Operation and Maintenance Support
- References
- Concepts
- Buttons
- Change RU to Local Mode
- Change RU to Remote Mode
- Change RU to Remote Mode Cancel
- Change SW Power Boost Slave RU to Local Mode
- Loop Control
- RF Loop Test Supervision
- Calendar Time Request
- RSSI Temperature Compensation
- Max Cooling
- Fault Indicator
- BS Fault Indicator
- Operational Indicator
- Tx Not Enabled Indicator
- Local Mode Indicator
- External Alarms Indicator
- DC Disconnected Indicator
- Battery Mode Indicator
- Bat Disconnected Indicator
- AC Fault Indicator
- Test Result Indicators (not used)
- Local Mode in Progress
- Installation Data Handling
- Self Test and Supervision
- Diagnostics and Fault Handling
- Operation and Maintenance Terminal
- External Alarms
- Handling of Auxiliary Equipment
- Climate Protection
- EMC Capabilities
- Transmission Interface Handling G.703 2048 kbit/s
- Transmission Interface Handling DS1 1544 kbit/s
- Terrestrial Link Handling
- Channel Distribution Function
- Transport network O&M functions-DXX Support
- BTS Parameter Limitations
- Glossary
Restart and Recovery
CMRU Central Main Replaceable Unit
An RBS has one CMRU.
DMRU Distributed Main Replaceable Unit
A Main RU is distributed if it is
subordinated to the CMRU.
35.3 Function
35.3.1 Purpose
The entire RBS is brought into operation in a controlled manner. The
sequence of events is given below.
35.3.2 Description
The sequence of actions initiated is summarized below:
1
start CMRU-processor
2
start DMRU-processor
3
start Sub RU-processor (if any)
4
start CMRU basic functions
5
start DMRU basic functions
6
start Sub RU basic functions
7
conditional RBS DB(Data base)load
8
read parameters for OM bus
9 define OM address
10 link establish functions for Sub RUs connected to DMRU
11 link establish functions for Sub RUs connected to CMRU
12
update RBS database for Sub RUs connected to CMRU
13
link establish functions for all expected DMRUs
14
update RBS database for all expected DMRUs
15 update RBS database for Sub RUs connected to DMRU
16 wait for expected Passive RUs
17 internal configuration
18 check RBS operational ability
19 set fault indicator on all DMRUs with faults
20 set operation indicator on all DMRUs with no faults
21 set fault indicator on all Sub RUs with faults
22 set fault indicator on all DMRUs with faults
23 bring CMRU into remote operation
270 (421)
EN/LZT 720 0008 R1A
2001-06-26
© Ericsson Radio Systems AB
— All Rights Reserved —