Reference Manual
Table Of Contents
- RBS 2206 Reference Manual
- Contents
- Preface
- Product Safety Requirements RBS 2000
- Environmental Capabilities
- Scope
- Terminology
- References
- Transport -40 C - +70 C
- Storage -25 C - +55 C
- Handling -40 C - +70 C
- Operation Indoor +5 C - +40 C
- Operation Outdoor -33 C - +40 C
- Operation Outdoor -33 C - +45 C
- Operation Outdoor -33 C - +55 C
- Operation Mast Mounted Equipment -33 C - +45 C
- Operation Mast Mounted Equipment -33 C - +55 C
- Radio Configurations, RBS 2206
- Product Data
- Unit Description, DXU-21
- Unit Description, dTRU
- Unit Decription, CDU-G and CDU-F
- Unit Description, CXU-10
- Unit Description, FCU-01
- Unit Description, DC-Filter 01
- Unit Description, PSU 1200 W
- Unit Description, ACCU/DCCU
- Unit Description, IDM
- Broadcast
- Common Control Channel Handling
- Physical Channel Handling
- Speech and Data Services
- Packet Data Services
- Call Control
- References
- Channel Activation
- Adaptive Frame Alignment
- Asynchronous Handover Detection
- RF Channel Release
- Deactivate SACCH
- Link Establish Indication
- Link Release Indication
- Link Establishment Request
- Link Release Request
- Transparent Message Transmission
- Transparent Message Reception
- SACCH Info Modify
- LAPDm
- Channel Reactivation
- Power Information
- GPRS, Physical Link Layer
- Base Station Power Control
- Channel Measurements
- Discontinuous Transmission
- Frequency Hopping
- Encryption
- Mode Modify
- Mobile Station Power Control
- Short Message Service
- Diversity Supervision
- Synchronization
- Radio Reception
- Radio Transmission
- Frequency Allocation Support
- Restart and Recovery
- Function Change
- Functionality Administration
- Operation and Maintenance Support
- References
- Concepts
- Buttons
- Change RU to Local Mode
- Change RU to Remote Mode
- Change RU to Remote Mode Cancel
- Change SW Power Boost Slave RU to Local Mode
- Loop Control
- RF Loop Test Supervision
- Calendar Time Request
- RSSI Temperature Compensation
- Max Cooling
- Fault Indicator
- BS Fault Indicator
- Operational Indicator
- Tx Not Enabled Indicator
- Local Mode Indicator
- External Alarms Indicator
- DC Disconnected Indicator
- Battery Mode Indicator
- Bat Disconnected Indicator
- AC Fault Indicator
- Test Result Indicators (not used)
- Local Mode in Progress
- Installation Data Handling
- Self Test and Supervision
- Diagnostics and Fault Handling
- Operation and Maintenance Terminal
- External Alarms
- Handling of Auxiliary Equipment
- Climate Protection
- EMC Capabilities
- Transmission Interface Handling G.703 2048 kbit/s
- Transmission Interface Handling DS1 1544 kbit/s
- Terrestrial Link Handling
- Channel Distribution Function
- Transport network O&M functions-DXX Support
- BTS Parameter Limitations
- Glossary
Mobile Station Power Control
• Order MS to set the commanded power level
Description
The function is initiated when a CHANNEL_ACTIVATION message /
GSM:08.58:8.4.1/ containing MS Power is received from the BSC.
The value of the ordered MS power /GSM:08.58:9.3.13/ is passed
transparently to the MS.
RBS stores the MS power level received from BSC and includes it in
the L1 header of all downlink SACCH blocks /GSM:04.04:7.1/.
28.2.2 MS Power Control for an Active Channel
Supported channel numbers and Supported channel combinations /
GSM:05.02:6.4/, see the section above.
RBS actions:
•
Interpretation of the MS_POWER_CONTROL message
•
Storage of MS power level
•
Order MS to set the commanded power level
Description
The function is initiated when an MS_POWER_CONTROL message /
GSM:08.58:8.4.15/ containing MS Power is received from the BSC for
an active dedicated channel.
The value of the ordered MS Power /GSM:08.58:9.3.13/ is passed
transparently to the MS.
The MS Power parameters /GSM:08.58:9.3.31/ is not supported by the
RBS.
RBS stores the MS power level received from BSC and includes it in
the L1 header of all downlink SACCH blocks /GSM:04.04:7.1/. It
overwrites the MS power value set by any previous "Channel
Activation" or "MS Power Control" functions.
28.2.3 MS Power Control at Channel Reactivation
SeeSection 28.2.1 on page 237.
238 (421)
EN/LZT 720 0008 R1A
2001-06-26
© Ericsson Radio Systems AB
— All Rights Reserved —