Reference Manual
Table Of Contents
- RBS 2206 Reference Manual
- Contents
- Preface
- Product Safety Requirements RBS 2000
- Environmental Capabilities
- Scope
- Terminology
- References
- Transport -40 C - +70 C
- Storage -25 C - +55 C
- Handling -40 C - +70 C
- Operation Indoor +5 C - +40 C
- Operation Outdoor -33 C - +40 C
- Operation Outdoor -33 C - +45 C
- Operation Outdoor -33 C - +55 C
- Operation Mast Mounted Equipment -33 C - +45 C
- Operation Mast Mounted Equipment -33 C - +55 C
- Radio Configurations, RBS 2206
- Product Data
- Unit Description, DXU-21
- Unit Description, dTRU
- Unit Decription, CDU-G and CDU-F
- Unit Description, CXU-10
- Unit Description, FCU-01
- Unit Description, DC-Filter 01
- Unit Description, PSU 1200 W
- Unit Description, ACCU/DCCU
- Unit Description, IDM
- Broadcast
- Common Control Channel Handling
- Physical Channel Handling
- Speech and Data Services
- Packet Data Services
- Call Control
- References
- Channel Activation
- Adaptive Frame Alignment
- Asynchronous Handover Detection
- RF Channel Release
- Deactivate SACCH
- Link Establish Indication
- Link Release Indication
- Link Establishment Request
- Link Release Request
- Transparent Message Transmission
- Transparent Message Reception
- SACCH Info Modify
- LAPDm
- Channel Reactivation
- Power Information
- GPRS, Physical Link Layer
- Base Station Power Control
- Channel Measurements
- Discontinuous Transmission
- Frequency Hopping
- Encryption
- Mode Modify
- Mobile Station Power Control
- Short Message Service
- Diversity Supervision
- Synchronization
- Radio Reception
- Radio Transmission
- Frequency Allocation Support
- Restart and Recovery
- Function Change
- Functionality Administration
- Operation and Maintenance Support
- References
- Concepts
- Buttons
- Change RU to Local Mode
- Change RU to Remote Mode
- Change RU to Remote Mode Cancel
- Change SW Power Boost Slave RU to Local Mode
- Loop Control
- RF Loop Test Supervision
- Calendar Time Request
- RSSI Temperature Compensation
- Max Cooling
- Fault Indicator
- BS Fault Indicator
- Operational Indicator
- Tx Not Enabled Indicator
- Local Mode Indicator
- External Alarms Indicator
- DC Disconnected Indicator
- Battery Mode Indicator
- Bat Disconnected Indicator
- AC Fault Indicator
- Test Result Indicators (not used)
- Local Mode in Progress
- Installation Data Handling
- Self Test and Supervision
- Diagnostics and Fault Handling
- Operation and Maintenance Terminal
- External Alarms
- Handling of Auxiliary Equipment
- Climate Protection
- EMC Capabilities
- Transmission Interface Handling G.703 2048 kbit/s
- Transmission Interface Handling DS1 1544 kbit/s
- Terrestrial Link Handling
- Channel Distribution Function
- Transport network O&M functions-DXX Support
- BTS Parameter Limitations
- Glossary
Unit Description, PSU 1200 W
Table 93
Indicator
Colour
Fault Red
Operational Green
EPC bus fault
Yellow
12.1.5 Input Data
Table 94 Input data
Nominal input voltage
120 to 250 V AC
Permitted variation input voltage
108
1)
to 275 V AC
Frequency 45-65 Hz
Current < 8A (at 180 - 275 V AC)
<12 A (at 108 - 140 V AC)
Inrush current
< 30 A peak
Internal fuse 15 A (slow)
Efficiency
> 83%
Power factor
cos ϕ > 0.95
Non-destructive voltage
0 - 300 V AC
Pulses < 20 ms
300 V AC
Max. power consumption 1446 V A
Max. heat generation 246 W
1)
90 V AC with reduced output power.
12.1.6 Output Data
Table 95 Output data
Nominal output voltage
+24 V DC
Preset output voltage
+27.2 ±0.1 V DC
Voltage range
+22 to +29 V DC
Ouput power (108 - 275 V)
1200 W
Output power (90 - 108 V)
1000 W
Output current at 27.2 V DC 36.8 A at 90 - 108 V AC
44.1 A at 108 - 275 V AC
12.1.7 Dimensions and Weight
Table 96 PSU Dimensions and weight
Height
262 mm
Width 61 mm
Depth
225 mm
Weight 3.3 kg
EN/LZT 720 0008 R1A
2001-06-26
147 (421)
© Ericsson Radio Systems AB
— All Rights Reserved —