Reference Manual

Table Of Contents
Unit Description, CXU-10
The CXU is also connected to a CDU-bus. By sending data through the
CDU-Bus, the switches can be set to full one of six supported
congurations.
Inside the CXU there are also some splitters to distribute the incoming
RX-signals to the switches and in some cases directly to an out port.
The RF cables between CDU and CXU are supervised in the CXU. The
RF cables between CXU and dTRU are supervised in the dTRU.
The CDU-bus cable is monitored by the DXU.
9.3 External Interfaces
The CXU has the following connectors:
Six inputs for RX signals from the CDU
Twelve output ports for RX signals to dTRU
CDU-bus connector for alarm and conguration settings
Power supply connector
The CXU has the following indicators:
Operational green
Fault red
RXI TRU1 RX2 RXI CDU RX2 RXI TRU2 RX2 RXI TRU3 RX2 RXI TRU4 RX2RXI CDU2 RX2 RXI TRU5 RX2 RXI CDU3 RX2 RXI TRU6 RX2
Oper Fault
DC/CD U3 CDU bus
CXU-10 900
P007458A
Figure 73 CXU-10, external interfaces
9.4 Technical Data
Table 84 Technical data
Height 22 mm
Width 482.6 mm
Depth 120 mm
1)
Weight 2kg
Max. power consumption 10 W
1)
The CXU protrudes 40 mm in front of the magazine.
136 (421)
EN/LZT 720 0008 R1A
2001-06-26
© Ericsson Radio Systems AB
All Rights Reserved